Search Results

Search found 17761 results on 711 pages for 'custom binding'.

Page 466/711 | < Previous Page | 462 463 464 465 466 467 468 469 470 471 472 473  | Next Page >

  • sp_releaseapplock timeout expired cause?

    - by Darian Miller
    I've been using a combination of sp_getapplock and sp_releaseapplock for some custom application locking purposes for years now with success and just the last few days I've started to get some timeout expired errors on a sp_releaseapplock which is a bit puzzling. When listing the current locks, there's less than a dozen of these active, and the rest of the dedicated server is way underutilized at the moment (less than 100 batches/sec with a mutli-processor, 32GB Ram, higher end machine.) Is there a specific resource to be monitored that may point me in the right direction for determing why such a lightweight operation is timing out? This is called within a stored proc with a timeout of 120 seconds which seems to be amazingly long for this operation to timeout on. SQL 2000 SP4 running on Windows 2003 Server. TSQL used (@pLockUniqueName is VarChar(255)) EXEC @pLockSuccess = sp_getapplock @pLockUniqueName, 'Exclusive', 'Session', 0 EXEC @pUnLockSuccess = sp_releaseapplock @pLockUniqueName, 'Session' Thanks, Darian

    Read the article

  • I have to shard a mysql database. I want to start with 12 shards on 2 machines. What is the best w

    - by Tim
    All tables are InnoDb. I would rather not use mysqldump, because the shard sizes will be about 200 GB (about 700 million rows), and that will take too long. I was hoping to just stop mysql for an hour, copy the data files to a new machine, and start back up. But you can't do this with InnoDb, as some data is in the shared tablespace. Even if I have the innodb_file_per_table option set. This is not a website, but a custom application, used by tens of thousands right now, so uptime and performance are important. I suppose I could add logic into my server application to allow for gradual rebalancing / moving of a shard. Does anyone have a better idea?

    Read the article

  • mini-dinstall chmod 0600 changes file: Operation not permitted

    - by V. Reileno
    I'm getting "Operation not permitted" in the mini-dinstall.log everytime a new debian package has been uploaded on the custom debian repository using dput. The deb file is installed successfuly but the changes file remains in the incoming folder. I can not use a post-install script when the changes file can not be processed. How can I fix this problem? Traceback (most recent call last): File "/usr/bin/mini-dinstall", line 780, in install retval = self._install_run_scripts(changefilename, changefile) File "/usr/bin/mini-dinstall", line 826, in _install_run_scripts do_chmod(changefilename, 0600) File "/usr/bin/mini-dinstall", line 193, in do_chmod do_and_log('Changing mode of "%s" to %o' % (name, mode), os.chmod, name, mode) File "/usr/bin/mini-dinstall", line 176, in do_and_log function(*args) OSError: [Errno 1] Operation not permitted: '/srv/debian-repository/mini-dinstall/incoming/debian-repository_1.3_amd64.changes' The mini-dinstall permissions: ls -lad incoming/ drwxrws--- 2 mini-dinstall debian-repository-uploader 4096 Jun 6 11:45 incoming/ ls -la incoming/debian-repository_1.3_amd64.changes -rw-rw---- 1 uploader-user debian-repository-uploader 1322 Jun 6 11:43 incoming/debian-repository_1.3_amd64.changes groups uploader-user uploader-user : uploader-user adm users debian-repository debian-repository-uploader puppet-client-updater groups mini-dinstall mini-dinstall : mini-dinstall debian-repository-uploader Cheers and thanks V.

    Read the article

  • ASP.NET MVC multi-instance session management on amazon ec2

    - by gandil
    I have a web application written in asp.net mvc2. Currently hosted on amazon cloud ec2. Because of growing traffic we want move multi instance enviorenment. I have a custom session class which currently initiate at session start (global asax) and i am using via getter or setter class in application. Because of multi instance chore i have to handle hole security architecture. I am looking a better way to handle this problem. I am looking for good implementation of session and how to apply on amazon ec2 multi instance environment. What is road blocks for system architecture?

    Read the article

  • What's the situation that requires stateful firewall?

    - by Eonil
    I just know there is two kind of firewalls. Stateless and stateful. It's hard to determine what kind of firewall I have to use. Currently I have to run firewall within same machine runs services, Basically I want stateless because of its less resource consumption. However if it is not sufficient for security, it's meaningless. I'll run HTTP, SSH, NFS (only over SSH), and some custom made server on several TCP/UDP ports. Should I use stateful firewall? (edit) Maybe the question can be assumed as 'Should I use stateful rules?'.

    Read the article

  • How can I see the structure of a webpage inline?

    - by Coldblackice
    How can I see a webpage's structure "inline" with the visual representation of the actual page, all at once? I'm trying to understand HTML layout better, but it's hard to get a feel for it, even having the source open on a separate monitor, because there's just so much expansive and miscellaneous code. I suppose I could sift through it, clean it up, and set up some type of custom collapsible tree system, but that would take too long for the amount of pages I'd like to get a quick view of the layout/structure of. For reference, I'm using Firefox for my internet browsing.

    Read the article

  • Issue with Visual C++ 2010 (Express) External Tools command

    - by espais
    Hi all, Normally we develop in VS 2005 Pro, but I wanted to give VS 2010 a spin. We have custom build tools based off of GNU make tools that are called when creating an executable. This is the error that I see whenever I call my external tool: ...\gnu\make.exe): *** couldn't commit memory for cygwin heap, Win32 error 487 The caveat is that it still works perfectly fine in VS2005, as well as being called straight from the command line. Also, my external tool is setup exactly the same as in VS 2005. Is there some setting somewhere that could cause this error to be thrown?

    Read the article

  • Windows: How to add batch-script action to Right Click menu

    - by ervingsb
    I have a few programs that creates temp files or backup files or similar files that are not important. For example, GVim for Windows by default creates a backup file in filename.txt~. I sometimes need to clean up a dir and remove all these files. I have made a simple .bat file for this. However, it is cumbersome to have to start up cmd, navigate to the folder, run the script. Especially since this is a script that I would like to run often on various folders. And I do not want to copy the script to multiple folders, as this would be a maintenance nightmare. So, I was thinking, that the best solution would be to add a Right Click menu item that allows me to run the script. So that I can right click on a folder in Explorer and click Cleanup and then have my script run on this folder. So my question is: How do I add a right click menu action that runs a custom batch script?

    Read the article

  • Virtual hosting in Varnish with individual vcl files for configuration

    - by Michael Sørensen
    I wish to use varnish to put in front of an apache and a tomcat on the same server. Depending on the ip requested, it goes to a different backend. This works. Now for most of the sites the default varnish logic will work just fine. However for some specific sites I wish to use custom VCL code. I can test for host name and include config files for the specific domains, but this only works inside the individual methods recv etc. Is there a way to include a complete set of instructions, in one file, per domain, without having to manage separate files for subdomain_recv, subdomain_fetch etc? And preferably without running seperate instances of varnish. When I try to include a file on the "root level" of default.vcl, I get a compilation error. Best regards, Michael

    Read the article

  • Is the 4-pin PSU connector required? (Trying to connect a PSU to a mini case.)

    - by Geeks On Hugs
    I am trying to build a computer, placing an ASUS P8H67-I DELUXE in a custom retro C64 case. The case is an extra small form factor which can accomodate the Mini ITX board, but requires an external power supply, similar to the power-bricks that laptops use. I am looking at different power supplies and like these, but cannot figure out whether/how to power this system because they provide a 24-pin connector, but the motherboard has a 4-pin connector as well. Is the 4-pin connector optional or is it required? If it is required, how can I provide power for this system?

    Read the article

  • Good firefox extension to download .flv flash video?

    - by Tamás Szelei
    I'm looking for a decent flash video downloader for Firefox. There are tons of them. I'd like to use it for a custom site with some random flash video player, not Youtube. How can it be accomplished? Edit: None of these methods you guys suggested worked so far; I looked up various places where the temporary file might end up - it just doesn't. It is indeed a flash player, but it seems like it's not caching - is that possible?

    Read the article

  • How to have 2 windows machines on the same network with the same IP address

    - by Stu
    I have a custom made ADC device that is spitting out data by addressed UDP packets. I have that device plugged into a 4 port switch. I have one windows embedded standard 7 machine which is the normal recipient of that data. To be able to receive the data (Using LabVIEW) the windows network adapter IPv4 settings must have a static IP address that corresponds to the UDP packet destination. I would like to add a second windows machine (This one is just regular Win 7 Pro) to simultaneously catch the data, however with all devices connected to the switch, the Win 7 Pro machine recognizes an IP address conflict and will not take the setting for the required static IP address. (The network adaptor settings show that the correct value has been entered but ipconfig shows that it is not actually set.) Neither windows machine needs to transmit network data, they only need to be able to receive the UDP data from the ADC device. Is there any way to disable this IP address conflict detection 'feature' of windows networking?

    Read the article

  • Multiple foldmethods in vim

    - by bjarkef
    I use the folding option of vim quite a lot, and have usually set foldmethod to syntax. Recently I discovered that it is possible to add custom folds, such that I can put whole blocks in /*{{{*/ and /*}}}*/ which is very useful for grouping large sections of a source file together. However to use that feature I need to set foldmethod to marker, and I loose the syntax folding. Is it possible to have two active foldmethods at the same time in vim? set foldmethod=syntax,marker does not work.

    Read the article

  • SharePoint MOSS - Serve HTTP content on an HTTPS page without Mixed Content Warning?

    - by kcb263
    Our "portal-like" SharePoint site is served using HTTPS/SSL. So a user goes to https://web.company.com and sees content and different Web Parts. So far, no problem. The desire now is to have new Web Parts added that either frame HTTP content (such as Weather Bug) or HTTP RSS feeds. The issue that arises is that by doing this, results in a "Mixed Content" warning in the browser. Has anybody successfully been able to implement such a scenario, or one similar to it? The options we have looked at, unsuccessfully, have been: using Apache Reverse Proxy Server mirror an external site Custom Web Parts

    Read the article

  • Gnome 3 screensaver (not suspend) resume hook?

    - by Daniel
    Since whenever my laptop screen resumes sleeping (i.e. wakes up from screensaving) some settings are reset, such as keyboard backlight, I'd like to run some scripts each time this happens. I'm using gnome 3 with fedora 17 by the way. When researching this issue I came across pm-utils which allows one to hook anything to events handled by pm-utils but it seems to me monitor sleeping (i.e. screensaving) is not one of them. Looks like pm-utils only handles suspend and hybernate. So is there a way to hook up custom programs to screensaver?

    Read the article

  • Broken web interface in WRT54G router

    - by asmo
    I flashed my WRT54G (v3) from a custom firmware to the lastest Linksys one (v4.21.1) Now the internet/LAN works fine, but the web interface (http://192.168.1.1/) shows broken pages. I tried to manually navigating to the firmware upgrade page (by entering its URL), but it is broken too and not working. I tried a 30/30/30 reset twice, but the broken web interface still shows up. I tried to flash using the tftp2.exe application, which told me that the router didn't respond to the request. I tried to flash using the Windows commandline TFTP protocol, but I don't know how to supply a password on this prococol. (there is a factory default password ("admin") which I can't remove since the web interface is broken)

    Read the article

  • How can I generate a list of appendices with LaTeX, seperate from table of contents (toc)

    - by None
    LaTeX' appendix environment formats sections differently and uses a different enumeration in the table of contents: \begin{appendix} \section{superuser} \dots{} .... Shows up as       A       superuser            11 in the \tableofcontents. Unfortunately, I have to use a different style: the appendix is not to show up in the table of contents, but in a seperate listing right before the appendix. I see the following options to solve this: suppress output in tableofcontents and somehow recreate the part on a different page generate a custom listing of specified / the following section manually create a list with the same formatting of the tableofcontents I use scrartcl as document class. PS: appedix / appendices is not a tag yet

    Read the article

  • Microsoft Outlook 2007 - General Failure. The URL was: "<http:/something.com>". The parameter is incorrect

    - by Simon Peverett
    For the last two days, Outlook has decided it doesn't like URL's. Any email message that comes in containing an URL will show the following in an error dialogue message box when I click on the link: General Failure. The URL was: "http:/something.com/somewhere/". The parameter is incorrect If I copy the link into a browser, it works correctly. OS is Windows XP SP 3, Microsoft Office 2007 (Outlook), Internet Explorer 8 (also Chrome). I have, of course, Googled this and the two most popular solutions are: Solution 1: Add/Remove programs Set Program Access and Defaults Custom tab Make sure a default browser is selected Solution 2: Add/Remove Programs Select the MS Office 2007 item Click Change Click Repair I have tried both of these and I still get the problem. Has anyone else had this problem and solved it with a solution other than those listed above?

    Read the article

  • Context Menu for Browser to download file to specific folder

    - by elcojon
    There is this website which has customized audio files for me. I would like to save them in a special folder. Now I don't want to select the "special folder" each time in the file-chooser dialogue of my browser. I would rather prefer to have a custom entry in the context menu when I right-click the download link. This context-menu-entry should do the trick and download the file to the predefined "special folder". How would I start about that? I am using Safari and Chrome. So a solution in either browser is fine. To get into the context menu of the browser, what kind of programming do I need to do? Is it an extension, plugin, etc.? Thanks

    Read the article

  • VoIP on Netgear DGN 2000 and Lynksys PAP2

    - by David Brown
    I have a VoIP service running perfectly for outgoing calls but I cannot receive incoming calls. I have a Netgear DGN 2000 modem router on 192.168.0.1 and a Lynksys Phone Adapter PAP2 on 192.168.0.2. I have created 3 new custom services: Service Table Service Name Ports tlenfon(TCP) 5060 tlenfon2(UDP) 15000 tlenfon3(UDP) 35000 I have reserved the address 192.168.0.2 for the PAP 2 I have forwarded the ports for each service to the PAP2 Service Name Action LAN Server IP address WAN Users Log tlenfon ALLOW always 192.168.0.2 Any Always tlenfon2 ALLOW always 192.168.0.2 Any Always tlenfon3 ALLOW always 192.168.0.2 Any Always I have checked the Default DMZ and specified 192.168.0.2 What have I missed?

    Read the article

  • How to programmatically control slave computer on BIOS level?

    - by PovilasSid
    I want to run some test on hardware level. My goal is to create or find a way to control one computer from another down to BIOS settings changing. For example: Master computer sends a signal for slave to restart and opens BIOS settings dialog. Master computer sends a signal to slave to change BIOS parameters and then restart. Then slave fully boots up master starts up some software on slave. Then software finishes operations cycle continues till certain conditions are met. I know that I am looking for a complex thing but mainly what I need are correct keywords because now I am being flooded by BIOS configurations tutorials. Main concerns: Is it possible without using any custom tailer chip? How can master monitor salve`s hardware activity? How to let master handled more than one slave? How what connections are needed to create this kind of setup? (cables)

    Read the article

  • aws s3 works with script but not on cron

    - by user3800017
    guys.. My first post ! hope not the last .. I have few bunch of servers on aws ec2 platforms. I made a simple script to backup my custom logs on their s3 storage bucket. The problem is the script works fine .. but I tried to add it to the crontab. And the script executes but not the s3 sync/mv part ! Here is my code: NOW=$(date "+%b_%d_%Y") MY_HOSTNAME=`uname -n` mv /opt/req/req* /opt/req/bkup/ mv /opt/response/res* /opt/req/bkup/ cd /opt/req/bkup/ tar -cvf ${MY_HOSTNAME}_req_bkup_${NOW}.tar re* rm *.txt aws s3 mv /opt/req/bkup/* s3://req `

    Read the article

  • Labeling values in a GNUplot heatmap

    - by andremo
    I am trying to generate a heat map using gnu plot. set title "Heat Map" plot '-' matrix with image 10 20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100 0 30 40 50 60 70 80 90 100 0 0 40 50 60 70 80 90 100 0 0 0 50 60 70 80 90 100 0 0 0 0 60 70 80 90 100 0 0 0 0 0 70 80 90 100 0 0 0 0 0 0 80 90 100 0 0 0 0 0 0 0 90 100 0 0 0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0 e Along the axes I get values -2 0 2 4 6 8 10, and I would like to replace those with a custom string. I cannot find out how to do this.

    Read the article

  • Behaviour of disabling "Allow non-administrators to receive notifications" GPO

    - by Jaymz
    Hi everyone, As the title suggests, I'm trying to figure out the specific behaviour of the following GPO when disabled: Administrative Templates Windows Components Allow non-administrators to receive update notifications We've just started using WSUS, and have added a few machines for testing. At the moment, this is set to Enabled. The problem with this setting is it seems to allow users to opt out of certain updates if they deselect the checkbox after hitting custom install. My main concern with disabling this setting is this: Does it stop non-admins from getting the installs deployed to them? My guess would be that it will just install them silently at the set scheduled time, suppressing any prompts and ensuring they don't get the opportunity to cancel them (this is what I want). My worry is that non-admin users will never get updates pushed to them unless an admin goes and logs on to their machine (not what I want, and seems like a silly situation to be in). Thanks in advance, Jaymz.

    Read the article

  • Power supply issue? New Radeon5850's fan runs at full speed and PC doesn't boot.

    - by Kris
    I recently bought a new ASUS EAH5850 graphics board. I installed it a custom PC which had an ASUS p5n-e SLI mobo along with a 500w Thermaltake W0093RU power supply. Sometimes when doing a cold boot the 5850's fan will run at full speed and the PC will not boot. Powering off by holding down the power button and powering back on sometimes remedies the situation and everything boots normally. Warm reboots also never seem to have problems. For some reason though cold boots almost always do. Another issue I notice is that when the PC does boot normally it takes longer (+30 secs) to POST than with my last video card. I flashed the mobo with the latest available BIOS but it had no effect. Is my problem a power issue or incompatible motherboard or something else I'm missing?

    Read the article

< Previous Page | 462 463 464 465 466 467 468 469 470 471 472 473  | Next Page >