  • Determine Users Accessing a Shared Folder Using PowerShell

    - by MagicAndi
    Hi, I need to determine the users/sessions accessing a shared folder on a Windows XP (SP2) machine using a PowerShell script (v 1.0). This is the information displayed using Computer Management | System Tools | Shared Folders | Sessions. Can anyone give me pointers on how to go about this? I'm guessing it will require a WMI query, but my initial search online didn't reveal what the query details will be. Thanks, MagicAndi

    Read the article

  • WIN32_NetworkAdapterConfiguration does not report IP from PPP adapter

    - by Michael
    On a Windows 7 device, the following WMI query does not report back an enabled PPP adapter: Select Index,MACAddress,IPAddress,IPSubnet,DefaultIPGateway,DNSServerSearchOrder from Win32_NetworkAdapterConfiguration where IPEnabled=true Where ipconfig gives you all the information correctly: Windows IP Configuration PPP adapter XYZ VPN: Connection-specific DNS Suffix . : IPv4 Address. . . . . . . . . . . : 123.456.789.123 Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : 0.0.0.0 Wireless LAN adapter Wireless Network Connection: Connection-specific DNS Suffix . : IPv4 Address. . . . . . . . . . . : 192.168.178.11 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 192.168.178.1 Ethernet adapter Local Area Connection 3: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Any ideas how I can script this by using WMI or VBS?

    Read the article

  • I get Get-WmiObject : Generic Failure error on an XP Machine. What needs to be done to get rid of this?

    - by steeluser
    I am trying make an uninstall app which removes an application X on a regular basis. The starting point to access applications installed in a Windows machine is through retrieving them from a WMI Class called Win32_Product. But when I run the basic command like this, I get the below error. I have searched technet and SO, but either their workarounds did not work for me or were too technical in detail which did not make sense to me. Please help. SO Link ps$ Get-WmiObject -class win32_product IdentifyingNumber : {09959E11-AD5D-408E-96AF-E3346954D6B8} Name : Shared Add-in Extensibility Update for Microsoft .NET Framework 2.0 (KB908002) Vendor : Microsoft Version : 1.0.0 Caption : Shared Add-in Extensibility Update for Microsoft .NET Framework 2.0 (KB908002) Get-WmiObject : Generic failure At line:1 char:14 + Get-WmiObject <<<< -class win32_product + CategoryInfo : InvalidOperation: (:) [Get-WmiObject], ManagementException + FullyQualifiedErrorId : GetWMIManagementException,Microsoft.PowerShell.Commands.GetWmiObjectCommand

    Read the article

  • SQL Server 2005 Reporting Services - Configuration Manager & Management Studio Problems

    - by Nick
    When I open Reporting Services Configuration Manager on my server, an error message appears that says: Reporting Services Configuration Manager An unknown error has occurred in the WMI Provider. Error Code 800706B3 This error appears before I can even attempt to connect to an SSRS instance. In addition to this problem, I'm not able to connect to my SSRS instance via SSMS on my desktop. When I attempt to connect, I get the following error message: Microsoft SQL Server Management Studio Exception has been thrown by the target of an invocation. (mscorlib) Additional information: The operation could not be completed. (WinMgmt) Information about my environment: Server: Win Server 2K3 x64, SQL 2005 x64 SP3 Build 9.0.4053 Desktop: Windows 7 Enterprise x64 Steps I have already taken: I have installed the latest service pack on my server and workstation. I do not see any errors in my event logs.

    Read the article

  • Should I install Windows Management Framework 3.0?

    - by Massimo
    I'm posting this as a BIG CAVEAT to everyone. I know it's not a standard Q&A, but I think this is someone every Windows admin should know. There is a very real risk of falling into Big Troubles. Microsoft has recently released Windows Management Framework 3.0 for Windows Server 2008 and Windows Server 2008 R2 systems, which includes some nice things native to Windows Server 2012 (like PowerShell 3.0) and lots of improvements to WMI, WinRM and other management technologies. Windows Update is advertising it as an optional update. Should I install it on my servers?

    Read the article

  • wmic output well formed xml on remote queries

    - by Mervin
    I want to use the WMI command line tool (wmic) to get information about windows computers on the network and output it as valid xml. However, I can't seem to find the right way to do this as the outputted xml currently contains invalid tokens for which I think I should use the /TRANSLATE:basicxml switch. The command: wmic /NODE:"tech-demo" /IMPLEVEL:Impersonate /USER:MyUser /PASSWORD:MyPassword /PRIVILEGES:DISABLE /AUTHLEVEL:Pkt /AUTHORITY:"ntlmdomain:companydomain.local" PATH Win32_LogicalDisk GET * /FORMAT:rawxml This command runs but returns invalid xml tokens ('<' and '' I think? edit: it appears to fail parsing at ‹) When I add the translate switch I get the message: Can not use credentials for local connections a bit strange that it tries to query the local pc when I add the switch.. Help would be greatly appreciated.

    Read the article

  • How to set printer permissions using PowerShell / some other script?

    - by Borek
    I need to update printer's permissions in a script, i.e. do the same as I would manually do this way: Open Devices and Printers applet Double-click the default printer (open its queue) Go to Printer - Properties In the properties dialog, go to Security tab Change permissions for Everyone (e.g., check Manage documents permissions) How to do that? For example, in PowerShell, I can do Get-WmiObject -class win32_printer -filter Default=True to get the default printer and there are then methods getSecurityDescriptor() and setSecurityDescriptor() but for instance this command: (Get-WmiObject -class win32_printer -filter Default=True).getsecuritydescriptor().Descriptor return null so I'm not sure if I'm doing it the right way. Does anyone have a working example to set printer permissions? Am I on the right path or should I use something other than WMI entirely? Thanks.

    Read the article

  • Group policy results failing with "Invalid class" error

    - by bshacklett
    When trying to run the Group Policy Results Wizard against a specific workstation, I'm getting the following error: The wizard was unable to generate the computer or user's data due to insufficient permissions. Details: Invalid class I'm guessing that the class being referred to is a WMI class, but I haven't gotten much farther. I've run sfc /scannow on the machine with no luck. I've also followed all of the recommendations in this article: http://windowsxp.mvps.org/repairwmi.htm. I cannot find anything useful in the event logs and I can't think of anywhere else I could look to find out what's really happening here. Any help would be appreciated.

    Read the article

  • How to get cluster information remotely via Powershell?

    - by pdanke
    I've been trying to find a good way to gather various pieces of a windows cluster setup remotely, preferably via WMI, as we are not yet at a point where Powershell remoting is implemented (and I know this problem goes away with that). I know I can use the following to get the current node: Get-WmiObject Win32_ComputerSystem -ComputerName RemoteServer1 | Select Name I also need the name property of Get-Cluster, which I can't figure out how to get from a remote system. Is there something out there, or should I wait it out until Remoting gets implemented? I'm a newbie to all things clustering, just a dba looking to inventory our servers properly. Thanks for any help!

    Read the article

  • Adding/Removing Users For Permissions in XP

    - by Brian
    Hello, I have some specific folders that I grant members of my team permissions to. So I'll share a specific folder and add them as permissions. But after they are done I usually remove them from the list of permitted users. I was wondering if it's possible to setup a bat file to achieve this, to make my life easier. I was wondering if WMI or powershell has those kinds of capabilities. Just curious. Thanks.

    Read the article

  • How do I implement a remote system management app in .NET 3.5?

    - by leComte
    I need, within the next few days, to create a system management DLL to format a specified drive, and a test app (managed code)to call the DLL. This need to be implemented in .NET 3.5 / VS 2008. I am an absolute beginner and have been trying to get my head around COM and WMI, but both seem to have been superceded, and I need really basic, step-by-step guidance (i.e. "Click 'File New ... etc.) Any pointers to suitable search terms, tutorials, etc., would be greatly appreciated.

    Read the article

  • insert VBS variable within a single-quoted WMI query

    - by jiaoziren
    Hi all, I am really frustrated by the snippet below: Dim objFSO, varSrc, varDest, varExt Set objFSO = CreateObject("Scripting.FileSystemObject") varSrc = WScript.Arguments(0) varDest = WScript.Arguments(1) varExt = WScript.Arguments(2) If objFSO.FolderExists(varSrc) Then WScript.Echo varSrc strComputer = "." Set objWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2") Set colMonitoredEvents = objWMIService.ExecNotificationQuery _ ("SELECT * FROM __InstanceCreationEvent WITHIN 10 WHERE " _ & "Targetinstance ISA 'CIM_DirectoryContainsFile' AND " _ & "TargetInstance.GroupComponent= " _ & "'Win32_Directory.Name=""c:\\\\kk ""'") Do Set objLatestEvent = colMonitoredEvents.NextEvent WScript.Echo objLatestEvent.TargetInstance.PartComponent Loop Else WScript.Echo "Bazinga" End If I tried to replace c:\\kk with varSrc however it seems impossible for WSH to recognize it in WMI query - not to mention it was within a single quote! I have tried chr(34) and it didn't work. Please help if possible. Much appreciated!

    Read the article

  • WmiPrvSE memory leak on Windows 2008 *R2*

    - by MichaelGG
    I've seen references on Windows 2008 to WmiPrvSE leaks, but nothing about Windows 2008 R2. We're running R2 on top of Hyper-V (2008). We are also running NSClient++ for monitoring from opsview. Over time, WmiPrvSE.exe starts to use a lot of memory, causing memory alert issues (less than 10% free). VM has 2GB, WmiPrvSE consumes up to 500-600MB before I kill it. Killing the process doesn't seem to have any negative effect; it starts up again and I haven't noticed any problems. But after a day or two, it's back in the same situation. Any ideas on what to do? Resource Monitor doesn't show any Disk or Network IO by WmiPrvSE.exe. Just slowly climbing private memory... Edited to add: We aren't running clustering, or Windows System Resource Manager. The only regular WMI user I can guess is NSClient++, but we don't seem to have this problem on other servers.

    Read the article

  • availability of Win32_MountPoint and Win32_Volume on Windows XP?

    - by SteveC
    From the MSDN articles I've found -- http://msdn.microsoft.com/en-us/library/aa394515(v=VS.85).aspx -- Win32_Volume and Win32_MountPoint aren't available on Windows XP. However, I'm developing a C# app on Windows XP (64bit), and I can get to those WMI classes just fine. Users of my app will be on Windows XP sp2 with .Net 3.5 sp1. Googling around, I can't determine whether I can count on this or not. Am I successful on my system because of one or more of the following: - windows xp service pack 2? - visual studio 2008 sp1 was installed? - .Net 3.5 sp1? Should I use something other than WMI to get at the volume/mountpoint info? Below is sample code that's working... public static Dictionary<string, NameValueCollection> GetAllVolumeDeviceIDs() { Dictionary<string, NameValueCollection> ret = new Dictionary<string, NameValueCollection>(); // retrieve information from Win32_Volume try { using (ManagementClass volClass = new ManagementClass("Win32_Volume")) { using (ManagementObjectCollection mocVols = volClass.GetInstances()) { // iterate over every volume foreach (ManagementObject moVol in mocVols) { // get the volume's device ID (will be key into our dictionary) string devId = moVol.GetPropertyValue("DeviceID").ToString(); ret.Add(devId, new NameValueCollection()); //Console.WriteLine("Vol: {0}", devId); // for each non-null property on the Volume, add it to our NameValueCollection foreach (PropertyData p in moVol.Properties) { if (p.Value == null) continue; ret[devId].Add(p.Name, p.Value.ToString()); //Console.WriteLine("\t{0}: {1}", p.Name, p.Value); } // find the mountpoints of this volume using (ManagementObjectCollection mocMPs = moVol.GetRelationships("Win32_MountPoint")) { foreach (ManagementObject moMP in mocMPs) { // only care about adding directory // Directory prop will be something like "Win32_Directory.Name=\"C:\\\\\"" string dir = moMP["Directory"].ToString(); // find opening/closing quotes in order to get the substring we want int first = dir.IndexOf('"') + 1; int last = dir.LastIndexOf('"'); string dirSubstr = dir.Substring(first , last - first); // use GetFullPath to normalize/unescape any extra backslashes string fullpath = Path.GetFullPath(dirSubstr); ret[devId].Add(MOUNTPOINT_DIRS_KEY, fullpath); } } } } } } catch (Exception ex) { Console.WriteLine("Problem retrieving Volume information from WMI. {0} - \n{1}",ex.Message,ex.StackTrace); return ret; } return ret; }

    Read the article

  • Win XP error 0x80041003 using GetObject/winmgmts

    - by John Lewis
    My computer is called "neil" and I want to set some values using WMI in vbScript. I adapetd the script below from one supplied by Microsoft. When I run it in my browser I get Error Type: (0x80041003) /dressage/30/pdf2.asp, line 8 I suspect it is some registry/security setting. Any advice? John Lewis FULL SCRIPT call Print_HTML_Page("http://neil/dressage/ascii.asp", "ascii") Sub SetPDFFile(strPDFFile) Const HKEY_LOCAL_MACHINE = &H80000002 strKeyPath = "SOFTWARE\Dane Prairie Systems\Win2PDF" strComputer = "." Set objReg=GetObject( _ "winmgmts:{impersonationLevel=impersonate}!\\" & _ strComputer & "\root\default:StdRegProv") strValueName = "PDFFileName" objReg.SetExpandedStringValue HKEY_LOCAL_MACHINE,_ strKeyPath,strValueName,strPDFFile End Sub Sub Print_HTML_Page(strPathToPage, strPDFFile) SetPDFFile( strPDFFile ) Set objIE = CreateObject("InternetExplorer.Application") 'From http://www.tek-tips.com/viewthread.cfm?qid=1092473&page=5 On Error Resume Next strPrintStatus = objIE.QueryStatusWB(6) If Err.Number 0 Then MsgBox "Cannot find a printer. Operation aborted." objIE.Quit Set objIE = Nothing Exit Sub End If With objIE .visible=0 .left=200 .top=200 .height=400 .width=400 .menubar=0 .toolbar=1 .statusBar=0 .navigate strPathToPage End With 'Wait until IE has finished loading Do while objIE.busy WScript.Sleep 100 Loop On Error Goto 0 objIE.ExecWB 6,2 'Wait until IE has finished printing WScript.Sleep 2000 objIE.Quit Set objIE = Nothing End Sub

    Read the article

  • Getting the .NET Class associated with a process

    - by John P. Grieb
    As part of a WMI Coupled provider that I'm creating I need to write an instance enumerator. The code I have is below. What I need to do is get the Class instance associated with the process. Any ideas? static public WMIProviderSample GetInstance([ManagementName("ID")] int processId) { try { Process[] processes = Process.GetProcessesByName("WMI Provider Sample"); foreach (Process process in processes) { if (process.Id == processId) { // Need to convert the process to an instance of WMIProviderSampel } } return null; } catch (ArgumentException) { return null; } }

    Read the article

  • Dell OMCI: Wacky values for Temperature and etc? (Win7x64)

    - by Yablargo
    Hey All. I am running a Dell Precision R5400 Workstation with dell OMCI installed. I am using it to test polling various data over WMI for our monitoring across the enterprise. I'm getting some weird results. perhaps someone can help point me in the direction of some clarification? Posted is the results of my DCIM\SYSMAN\DCIM_NumericSensor probe for sensor type 2(temp sensor) Microsoft (R) Windows Script Host Version 5.8 Copyright (C) Microsoft Corporation. All rights reserved. ----------------------------------- DCIM_NumericSensor instance ----------------------------------- Accuracy: AccuracyUnits: AdditionalAvailability: Availability: AvailableRequestedStates: BaseUnits: 2 Caption: CommunicationStatus: CreationClassName: DCIM_NumericSensor CurrentReading: -214748365 CurrentState: Unknown Description: DetailedStatus: DeviceID: Root/MainSystemChassis/TemperatureObj ElementName: Temperature Sensor:CPU0 EnabledDefault: 2 EnabledState: 2 EnabledThresholds: ErrorCleared: ErrorDescription: HealthState: 5 Hysteresis: IdentifyingDescriptions: InstallDate: IsLinear: LastErrorCode: LocationIndicator: LowerThresholdCritical: LowerThresholdFatal: LowerThresholdNonCritical: MaxQuiesceTime: MaxReadable: MinReadable: Name: NominalReading: NormalMax: NormalMin: OperatingStatus: OperationalStatus: 2 OtherEnabledState: OtherIdentifyingInfo: OtherSensorTypeDescription: PollingInterval: PossibleStates: Unknown,Normal,Fatal,Lower Non-Critical,Upper Non-Critical,Lower Critical,Upper Critical PowerManagementCapabilities: PowerManagementSupported: PowerOnHours: PrimaryStatus: ProgrammaticAccuracy: RateUnits: 0 RequestedState: 12 Resolution: SensorType: 2 SettableThresholds: Status: StatusDescriptions: StatusInfo: SupportedThresholds: SystemCreationClassName: DCIM_ComputerSystem SystemName: dt:5Q7BKK1 TimeOfLastStateChange: Tolerance: TotalPowerOnHours: TransitioningToState: 12 UnitModifier: 0 UpperThresholdCritical: UpperThresholdFatal: UpperThresholdNonCritical: ValueFormulation: 2 I'm not really sure whats going on, but note the CurrentReading: -214748365. I have reinstalled OMCI a few times, installed the OMCI 7x compatability and same thing I consistently get that error. It almost looks like its a issue between 32/64 bit value or something? Do I have to convert it to a float ? :)

    Read the article

  • Difference between CurrentClockSpeed and MaxClockSpeed

    - by Ben
    Rationale this belongs on ServerFault rather than StackOverflow - I already have my program which gets the value, I am querying the value returned and what it means. I have an in-house program which audits our company PCs, and one of the things it checks is the speed of the processor. To do this, it queries the Win32_Processor WMI class and gets the value of CurrentClockSpeed. We were playing with the data today and found an anomaly with some of the speeds being reported incorrectly (for example, CurrentClockSpeed said 1.0GHz, whereas the CPU name said Intel(R) Core(TM)2 CPU T5600 @ 1.83GHz [Confirmed it is in fact 1.83GHz]). I did a bit of digging on the internet and found this blog post which might explain what is going on. My initial thought was that I could change the program to instead get the value for MaxClockSpeed instead of CurrentClockSpeed, but Microsoft's documentation doesn't clearly define what this will return. What I mean by that is will this return a value which is its actual maximum speed (say if it were overclocked) but which it would not normally be running at, or would it return what I expect, which is its maximum speed under normal (not overclocked) conditions?

    Read the article

  • copying files from one windows server to another

    - by Saju Pillai
    I have to copy a file from a windows 2008 server to one or more windows 2008 servers. I have accounts on the target machines with enough privileges to let me use powershell remoting and use wmi. The remote machines do not run ftp, ssh or similar file transfer mechanisms. I am not allowed to install software or run new services on the target server. I can run services on the source server. The file copy action must be initiated from the source server. i.e. I cannot manually logon to the target machines and initiate the copy - though an automated way to do this is acceptable. Is it possible to use WMI or PowerShell Remoting to push or pull the file from the source to the target ? Is it possible to invoke some sort of built in http client or invoke the BITS service/agent on the remote servers to pull files from the source server ? Other suggestions please.

    Read the article

  • How do I solve MSSQL 2008 install error, "The MOF compiler could not connect with the WMI server"?

    - by nbolton
    Possibly related to: SQL Server 2008 Install fails error reading etwcls.mof After manually removing MSSQL 2008 from my system (uninstall failed to remove two instances), I receive the following error when trying to re-install: The MOF compiler could not connect with the WMI server. This is either because of a semantic error such as an incompatibility with the existing WMI repository or an actual error such as the failure of the WMI server to start. It seems that mofcomp is failing with one of the .mof files, but I'm not sure which, or why. Digging through the connect article gave some indications, but no solution. I've run winmgmt /salvagerepository, which returns "WMI repository is consistent". Currently, I'm unable to install MSSQL 2008. Please help!

    Read the article

  • How do I solve MSSQL 2008 install error, "The MOF compiler could not connect with the WMI server"?

    - by nbolton
    Possibly related to: SQL Server 2008 Install fails error reading etwcls.mof After manually removing MSSQL 2008 from my system (uninstall failed to remove two instances), I receive the following error when trying to re-install: The MOF compiler could not connect with the WMI server. This is either because of a semantic error such as an incompatibility with the existing WMI repository or an actual error such as the failure of the WMI server to start. It seems that mofcomp is failing with one of the .mof files, but I'm not sure which, or why. Digging through the connect article gave some indications, but no solution. I've run winmgmt /salvagerepository, which returns "WMI repository is consistent". Currently, I'm unable to install MSSQL 2008. Please help!

    Read the article

  • Win XP error 0x80041003 using GetObject/winmgmts

    - by John Lewis
    My computer is called "neil" and I want to set some values using WMI in vbScript. I adapetd the script below from one supplied by Microsoft. When I run it in my browser I get Error Type: (0x80041003) /dressage/30/pdf2.asp, line 8 I suspect it is some registry/security setting. Any advice? John Lewis FULL SCRIPT call Print_HTML_Page("http://neil/dressage/ascii.asp", "ascii") Sub SetPDFFile(strPDFFile) Const HKEY_LOCAL_MACHINE = &H80000002 strKeyPath = "SOFTWARE\Dane Prairie Systems\Win2PDF" strComputer = "." Set objReg=GetObject( _ "winmgmts:{impersonationLevel=impersonate}!\\" & _ strComputer & "\root\default:StdRegProv") strValueName = "PDFFileName" objReg.SetExpandedStringValue HKEY_LOCAL_MACHINE,_ strKeyPath,strValueName,strPDFFile End Sub Sub Print_HTML_Page(strPathToPage, strPDFFile) SetPDFFile( strPDFFile ) Set objIE = CreateObject("InternetExplorer.Application") 'From http://www.tek-tips.com/viewthread.cfm?qid=1092473&page=5 On Error Resume Next strPrintStatus = objIE.QueryStatusWB(6) If Err.Number 0 Then MsgBox "Cannot find a printer. Operation aborted." objIE.Quit Set objIE = Nothing Exit Sub End If With objIE .visible=0 .left=200 .top=200 .height=400 .width=400 .menubar=0 .toolbar=1 .statusBar=0 .navigate strPathToPage End With 'Wait until IE has finished loading Do while objIE.busy WScript.Sleep 100 Loop On Error Goto 0 objIE.ExecWB 6,2 'Wait until IE has finished printing WScript.Sleep 2000 objIE.Quit Set objIE = Nothing End Sub Update: Thanks for your reply. The line breaks seem to have been introduced in the process of paasting into this form. Well spotted - I was using a PDF file name "ascii". I added a .pdf extension but still get the error. I suspect you're right that it's to do with admin rights. Here's more about the setup and what I'm trying to achieve. Win2pdf is a product for writing PDFs by works by simulating a Windows printer. You "print" the page, select win2pdf in the print dialog and it then asks for a file name. I have it installed on my pc (called Neil) and it works fine in this conventional way. My aim is to write an html page to a PDF file using win2pdf - but via ASP/vbscript/javascript rather than with manual intervention. The script for doing this was provided by win2PDF's tech support but when it did not work, that was the limit of their understanding. In the sample script the file ascii.asp just produces a table of ascii codes/characters. The URL given is on my own PC which has IIS set up to run scripts which it does fine. The error I get occurs on about the fourth line executed. I am logged in with full admin rights - I think! But I'm no expert. I hope this helps to give some more specific suggestions about how to check/fix the admin rights.

    Read the article

  • Launch command on remote Windows machine, given admin credentials

    - by Bilal Aslam
    I have a Windows Server 2008 instance on Amazon EC2 (Amazon's cloud compute platform, which provides VMs in the cloud). It has an external IP, and I have an admin account on the box. I would like to 'bootstrap' this instance remotely i.e. I want to run commands to download, install and configure apps on it, all without having to log on even once. I have figured out how to do this to a remote, domain-joined computer using WMI. I can even use psexec to get what I want, as long as the remote computer is part of the domain. However, I have NOT been able to do for a remote computer on EC2. Here are some specific restrictions: 1) The remote computer is not part of my domain, hence no Kerberos 2) The remote computer does not have a cert I trust, or vice versa I am sure I am running into to some auth/trust restriction. Is there any way I can run a single command on the remote, given that I have admin privileges? I'm not tied down to using WMI, but I do need to run a command somehow. Feels like this should be a solved problem.

    Read the article

  • Network Logon Issues with Group Policy and Network

    - by bobloki
    I am gravely in need of your help and assistance. We have a problem with our logon and startup to our Windows 7 Enterprise system. We have more than 3000 Windows Desktops situated in roughly 20+ buildings around campus. Almost every computer on campus has the problem that I will be describing. I have spent over one month peering over etl files from Windows Performance Analyzer (A great product) and hundreds of thousands of event logs. I come to you today humbled that I could not figure this out. The problem as simply put our logon times are extremely long. An average first time logon is roughly 2-10 minutes depending on the software installed. All computers are Windows 7, the oldest computers being 5 years old. Startup times on various computers range from good (1-2 minutes) to very bad (5-60). Our second time logons range from 30 seconds to 4 minutes. We have a gigabit connection between each computer on the network. We have 5 domain controllers which also double as our DNS servers. Initial testing led us to believe that this was a software problem. So I spent a few days testing machines only to find inconsistent results from the etl files from xperfview. Each subset of computers on campus had a different subset of software issues, none seeming to interfere with logon just startup. So I started looking at our group policy and located some very interesting event ID’s. Group Policy 1129: The processing of Group Policy failed because of lack of network connectivity to a domain controller. Group Policy 1055: The processing of Group Policy failed. Windows could not resolve the computer name. This could be caused by one of more of the following: a) Name Resolution failure on the current domain controller. b) Active Directory Replication Latency (an account created on another domain controller has not replicated to the current domain controller). NETLOGON 5719 : This computer was not able to set up a secure session with a domain controller in domain OURDOMAIN due to the following: There are currently no logon servers available to service the logon request. This may lead to authentication problems. Make sure that this computer is connected to the network. If the problem persists, please contact your domain administrator. E1kexpress 27: Intel®82567LM-3 Gigabit Network Connection – Network link is disconnected. NetBT 4300 – The driver could not be created. WMI 10 - Event filter with query "SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage 99" could not be reactivated in namespace "//./root/CIMV2" because of error 0x80041003. Events cannot be delivered through this filter until the problem is corrected. More or less with timestamps it becomes apparent that the network maybe the issue. 1:25:57 - Group Policy is trying to discover the domain controller information 1:25:57 - The network link has been disconnected 1:25:58 - The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator. 1:25:58 - Making LDAP calls to connect and bind to active directory. DC1.ourdomain.edu 1:25:58 - Call failed after 0 milliseconds. 1:25:58 - Forcing rediscovery of domain controller details. 1:25:58 - Group policy failed to discover the domain controller in 1030 milliseconds 1:25:58 - Periodic policy processing failed for computer OURDOMAIN\%name%$ in 1 seconds. 1:25:59 - A network link has been established at 1Gbps at full duplex 1:26:00 - The network link has been disconnected 1:26:02 - NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 3473457 minutes and DOUBLE THE REATTEMPT INTERVAL thereafter. 1:26:05 - A network link has been established at 1Gbps at full duplex 1:26:08 - Name resolution for the name %Name% timed out after none of the configured DNS servers responded. 1:26:10 – The TCP/IP NetBIOS Helper service entered the running state. 1:26:11 - The time provider NtpClient is currently receiving valid time data at dc4.ourdomain.edu 1:26:14 – User Logon Notification for Customer Experience Improvement Program 1:26:15 - Group Policy received the notification Logon from Winlogon for session 1. 1:26:15 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4. ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:18 - Computer details: Computer role : 2 Network name : (Blank) 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:19 - The WinHTTP Web Proxy Auto-Discovery Service service entered the running state. 1:26:46 - The Network Connections service entered the running state. 1:27:10 – Retrieved account information 1:27:10 – The system call to get account information completed. 1:27:10 - Starting policy processing due to network state change for computer OURDOMAIN\%name%$ 1:27:10 – Network state change detected 1:27:10 - Making system call to get account information. 1:27:11 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:27:13 - Computer details: Computer role : 2 Network name : ourdomain.edu (Now not blank) 1:27:13 - Group Policy successfully discovered the Domain Controller in 2886 milliseconds. 1:27:13 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu The call completed in 2371 milliseconds. 1:27:15 - Estimated network bandwidth on one of the connections: 0 kbps. 1:27:15 - Estimated network bandwidth on one of the connections: 8545 kbps. 1:27:15 - A fast link was detected. The Estimated bandwidth is 8545 kbps. The slow link threshold is 500 kbps. 1:27:17 – Powershell - Engine state is changed from Available to Stopped. 1:27:20 - Completed Group Policy Local Users and Groups Extension Processing in 4539 milliseconds. 1:27:25 - Completed Group Policy Scheduled Tasks Extension Processing in 5210 milliseconds. 1:27:27 - Completed Group Policy Registry Extension Processing in 1529 milliseconds. 1:27:27 - Completed policy processing due to network state change for computer OURDOMAIN\%name%$ in 16 seconds. 1:27:27 – The Group Policy settings for the computer were processed successfully. There were no changes detected since the last successful processing of Group Policy. Any help would be appreciated. Please ask for any relevant information and it will be provided as soon as possible.