  • Unclear pricing of Windows Azure

    - by Dirk
    How do you people think about the Windows Azure pricing model and the way it is presented to the user? I just found out that Azure keeps charging hours for STOPPED instances. I just received a bill from more than 100 euro for 3 STOPPED instances (not) running "HelloAzure". I the past I also played around with Amazon Web Services. Amazon doesn't charge for stopped instances. I was wondering: "Should I have known this before, or is Microsoft doing a bad job in clear communication in the pricing model?" Quote from http://www.microsoft.com/windowsazure/pricing/ : Compute time, measured in service hours: Windows Azure compute hours are charged only for when your application is deployed. When developing and testing your application, developers will want to remove the compute instances that are not being used to minimize compute hour billing. Partial compute hours are billed as full hours. I read this, so I stopped all instances after a few hours playing around. Now it seems I should have deleted them, not just "stopped". Strictly speaking, all depends on the definition of the word "deployed". If you upload an application, but it is not running, can it still be regarded as being "deployed"? May be, but when you read this for the first time, with AWS experience in mind, I don't think it's 100% clear what this means. Technically speaking, an uploaded application only uses (read: should only use / needs only) a few MB harddrive space. It doesn't require any CPU time. If Azure wants to reserve CPU's for not running instances.. well, that's Azure's choice, not mine. I don't want to spread a hate campaign at all, but I do want to know how people think about this subject. Should Microsoft be more clear about their pricing model or do you think it's clear enough? Second question: did anyone got refunded for a similar case? Thanks in advance! UPDATE 27-01-2011 I sent an email to customer support a few days ago, but I guess that didn't reach anu human being because I didn't hear anything from it. So, I made a telephone call today with a Dutch customer support representative (I live in Holland). She totally understood the problem and she's trying to get a refund for me. However, she mentioned that "usually these refund requests are denied", but she's going to try. She also mentioned that I'm not the first one with this (or similar) problem. UPDATE 28-01-2011 I just received a phonecall from Microsoft support. The lady told me some good news: the money will refunded. However, the invoice has not been made yet, and my creditcard will first be chardged, after which it will be refunded, but hey, that's no problem for me! I'm glad the way it's solved! Thanks everybody!

    Read the article

  • CORAID using only 1 of the 2 available NICs for AoE traffic

    - by Peter Carrero
    We got 6 CORAID shelves in my workplace. On 2 of them I see AoE traffic on only 1 of the 2 NICs that are attached to the SAN switch. We got jumbo frames enabled on all devices. Both NICs show up when I issue the aoe-interfaces command. This wouldn't bother me too much if the throughput performance observed on the "bad" shelves using bonnie++ wasn't half of the result of the "good" shelves. The "good" shelves are older SR1521 model and they have ReiserFS on their LUNS - not that I think it makes a difference - and the "bad" shelves are newer SR2421 model and have JFS. Any help as to what is going on and how to rectify this would be greatly appreciated. BTW: even the lower performing shelves outperform another iSCSI device we got, but that is another story... Thanks.

    Read the article

  • WD1000FYPS harddrive is marked 0 mb in 3ware (and no SMART)

    - by osgx
    After reboot my SATA 1TB WD1000FYPS (previously is was "Drive error") is marked 0 mb in 3ware web gui. Complete message: Available Drives (Controller ID 0) Port 1 WDC WD1000FYPS-01ZKB0 0.00 MB NOT SUPPORTED [Remove Drive] SMART gives me only Device Model and ATA protocol version 1 (not 7-8 as it must be for SATA) What does it mean? Just before reboot, when is was marked only with "Device Error", smart was: Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: WD-WCASJ1130*** Firmware Version: 02.01B01 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Mar 7 18:47:35 2010 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled SMART overall-health self-assessment test result: PASSED SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 188 186 021 Pre-fail Always - 7591 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 229 5 Reallocated_Sector_Ct 0x0033 199 199 140 Pre-fail Always - 3 7 Seek_Error_Rate 0x000e 193 193 000 Old_age Always - 125 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 16615 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 77 192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1564 193 Load_Cycle_Count 0x0032 146 146 000 Old_age Always - 164824 194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 What can be wrong with he? Can it be restored? PS new smart is === START OF INFORMATION SECTION === Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: [No Information Found] Firmware Version: [No Information Found] Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 1 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Mar 8 00:29:44 2010 MSK SMART is only available in ATA Version 3 Revision 3 or greater. We will try to proceed in spite of this. SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 82-83 don't show if SMART supported. Checking for SMART support by trying SMART ENABLE command. Command failed, ata.status=(0x00), ata.command=(0x51), ata.flags=(0x01) Error SMART Enable failed: Input/output error SMART ENABLE failed - this establishes that this device lacks SMART functionality. A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. PPS There was a rapid grow of " 192 Power-Off_Retract_Count " before dying. The hard was used in raid, with several hards from the same fabric packaging box (close id's). The hard drives were placed identically. Rapid means almost linear grow from 300 to 1700 in 6-7 hours. Maximal temperature was 41C. (thanks to munin's smart monitoring)

    Read the article

  • Register for windows Upgrade Offer from Windows 7 to Windows 8

    - by BumbleBee
    I have to register for windows Upgrade Offer from here. I purchased Dell Inspiron 5520 laptop before 2 weeks and I got windows 7 Home Basic in it. But now I want to register for windows upgrade offer, When I filled up registration form and submit then it displayed that I am not eligible for this kind of offer. I don't know why this message is displaying although I bought laptop in between eligible time period. I think, I was filling wrong details in form. Because I am not sure about what to fill in Retailer's Name, Purchase Date and PC Model. And one thing is how to find right purchase Date from my product's Service Tag ? Which date I have to fill in form, Shipping Date OR Manufacture Date? Please Provide me a right direction to register and correct information regarding Retailer'Name and Purchase Date and PC Model.

    Read the article

  • KVM machine does not start ssh, network is started, used to work

    - by lleto
    have been searching an pulling my hear out for the last 6 hours. I have a virtual machine that has been running fine for the last six months. I was happy ssh'ing into it and it was running a database and some small apps. Tonight ssh stopped working, so I decided to reboot the machine. I now have the following situation: virsh list --all states machine as running I can ping the machine and get a reply When I ssh to the machine I see "ssh: connect to host [myserver] port 22: Connection refused" nmap does not show port 22 as open I have tried to: - reboot the machine once more (no luck) - mount the filesystem and check /etc/ssh/sshd.conf (has not changed since working situation) - install virsh console, however this does not seem to work When I mount the fs directly using losetup the strange thing is that file dates seem to be frozen in /var/log/ around the time of the crash. If I look in /var/run/ I can see an sshd.pid, but the time is 6 hours ago (and numerous reboots). My virsh xml looks like this: <domain type='kvm' id='21'> <name>myserver</name> <uuid>09678c8d-a99b-1d18-a7af-88d027cc8f93</uuid> <memory>1048576</memory> <currentMemory>1048576</currentMemory> <vcpu>1</vcpu> <os> <type arch='x86_64' machine='pc-1.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>destroy</on_crash> <devices> <emulator>/usr/bin/kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/dev/disk01/myserver'/> <target dev='hda' bus='ide'/> <alias name='ide0-0-0'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <controller type='ide' index='0'> <alias name='ide0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:e3:13:86'/> <source bridge='br0'/> <target dev='vnet0'/> <model type='virtio'/> <alias name='net0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <serial type='pty'> <source path='/dev/pts/1'/> <target port='0'/> <alias name='serial0'/> </serial> <console type='pty' tty='/dev/pts/1'> <source path='/dev/pts/1'/> <target type='serial' port='0'/> <alias name='serial0'/> </console> <input type='mouse' bus='ps2'/> <graphics type='vnc' port='5900' autoport='yes' listen='127.0.0.1'> <listen type='address' address='127.0.0.1'/> </graphics> <video> <model type='cirrus' vram='9216' heads='1'/> <alias name='video0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </video> <memballoon model='virtio'> <alias name='balloon0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </memballoon> </devices> <seclabel type='dynamic' model='apparmor' relabel='yes'> <label>libvirt-09678c8d-a99b-1d18-a7af-88d027cc8f93</label> <imagelabel>libvirt-09678c8d-a99b-1d18-a7af-88d027cc8f93</imagelabel> </seclabel> </domain> I'm sort of lost as to where I can look to get the machine up and running again. On the same instance of kvm I have another server running which is working fine. Both are Ubuntu 12.04. All help is welcome....

    Read the article

  • Laptop battery: is voltage really important to respect?

    - by Marc-Andre R.
    I got an Acer Aspire 5100 and I just bought a new battery (after the stock battery just died yesterday). But I saw something after buying and I'm wondering whether it's really important or not. My stock battery was a 6-cell 4000mah 11.1v and the new battery is an 8-cell 4800mah 14.8v . I know that 8-cell and 4800mah is okay, but what about the 14.8v instead of 11.1v? The battery description says it's compatible with my laptop model (AS5100, model BL51), but the voltage difference makes me wonder. Will the laptop only take what it needs? Or will it be getting 14.8v straight in the brain? I know that my wall plug claims to output 19v, so logically I'm thinking a higher voltage battery shouldn't be a problem. Am I correct in thinking this? Thanks in advance for your answers!

    Read the article

  • USB hard drive doesn't graceful power off after eject on Windows 7

    - by Sim
    I have a couple of Seagate FreeAgent Go external USB hard drives and would like them to gracefully power off after ejecting in Windows 7. With Windows XP a few seconds after they are ejected they gracefully power off. When ejecting them on Windows 7 they just stay on and have to be physically disconnected before they lose power. I have checked the hard drive removal policy and it is set to quick removal. I have also looked in the Seagate forums but I couldn't find any info on this so I thought I'd ask the SuperUser community on any ideas why the difference and how to get the same behaviour in Windows 7 as in XP? Update: I am finding that this also happens with USB thumb drives as well. My current theory is that there were changes to the driver model with Vista/Win 7 that haven't been reflected in the device drivers yet. So things that worked under XP don't under Win7 as the drivers haven't been updated for the new model. Does that sound right?

    Read the article

  • Computer won't recognize second WD internal HD

    - by music man
    I installed a Western Digital Caviar Green 1TB internal hard drive, and want to use it for back up. My BIOS recognizes the device, but it is not recognized in Disk Management. It also is not recognized in "my computer." When I right-click my C drivepropertieshardware, I see it listed. First the drive was plugged into SATA port 1 on my motherboard, then I tried it in port 3, where it remains. I've been working on this for hours. Any help would be appreciated. More info Hard drive model #:WD10EADS-65M2B1 Windows 7 Home Premium 64 bit Service Pack 1 Computer:HP Model p6404y, Processor:AMD phenom II x4 820 2.80GHZ 8 gigs RAM

    Read the article

  • Inter-VLAN Malicious Code Scanning

    - by Jackthedog
    I am trying to find an inbuilt solution on a Cisco Catayst 3750X Switch to scan all traffic routed from one VLAN to another for malicious code. The situation is that we currently have a development environment which is currently being redesigned to upgrade the network infrastructure to use the 3750X switches to manage server and workstation connectivity as well as inter-VLAN routing. We also have another system that is responsible for taking the builds created on the development environment and imaging various HDDs. Because these are two separate systems, we have a requirement in the workplace to anti-virus scan any data transferred between these systems. This is done by copying the data from the originating system to external USB HDD, scanning in a standalone workstation and then copying the data on to the receiving system. As you can imagine this is extremely tedious and impractical most of the time... (I don't make the rules). Anyway, with this redesign going on, we would like to join the imaging system to the network infrastructure of the development system, keeping separation by the use of VLANs and restricting traffic by using ACLs. As we still have the requirement to scan all traffic I would like to configure some sort of malicious code scanning when ever traffic is routed between these VLANs. I am aware I could install a separate in-line IPS/IDS device, however both systems will be using multiple ports on the switch (obviously), and we won't be able to put a device on each port. I would would prefer not to add additional hardware if the 3750x switch is capable of doing the job. Is anyone aware of any Cisco solution that I could use here, that ideally can be incorporated into the 3750x switch? Thanks in advance.

    Read the article

  • KVM Slow performance on XP Guest

    - by Gregg Leventhal
    The system is very slow to do anything, even browse a local folder, and CPU sits at 100% frequently. Guest is XP 32 bit. Host is Scientific Linux 6.2, Libvirt 0.10, Guest XP OS shows ACPI Multiprocessor HAL and a virtIO driver for NIC and SCSI. Installed. CPUInfo on host: processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 42 model name : Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz stepping : 7 cpu MHz : 3200.000 cache size : 8192 KB physical id : 0 siblings : 8 core id : 0 cpu cores : 4 apicid : 0 initial apicid : 0 fpu : yes fpu_exception : yes cpuid level : 13 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx rdtscp lm constant_tsc arch_perfmon pebs bts rep_good xtopology nonstop_tsc aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 cx16 xtpr pdcm pcid sse4_1 sse4_2 x2apic popcnt tsc_deadline_timer aes xsave avx lahf_lm ida arat epb xsaveopt pln pts dts tpr_shadow vnmi flexpriority ept vpid bogomips : 6784.93 clflush size : 64 cache_alignment : 64 address sizes : 36 bits physical, 48 bits virtual power management: <memory unit='KiB'>4194304</memory> <currentMemory unit='KiB'>4194304</currentMemory> <vcpu placement='static' cpuset='0'>1</vcpu> <os> <type arch='x86_64' machine='rhel6.3.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <cpu mode='custom' match='exact'> <model fallback='allow'>SandyBridge</model> <vendor>Intel</vendor> <feature policy='require' name='vme'/> <feature policy='require' name='tm2'/> <feature policy='require' name='est'/> <feature policy='require' name='vmx'/> <feature policy='require' name='osxsave'/> <feature policy='require' name='smx'/> <feature policy='require' name='ss'/> <feature policy='require' name='ds'/> <feature policy='require' name='tsc-deadline'/> <feature policy='require' name='dtes64'/> <feature policy='require' name='ht'/> <feature policy='require' name='pbe'/> <feature policy='require' name='tm'/> <feature policy='require' name='pdcm'/> <feature policy='require' name='ds_cpl'/> <feature policy='require' name='xtpr'/> <feature policy='require' name='acpi'/> <feature policy='require' name='monitor'/> <feature policy='force' name='sse'/> <feature policy='force' name='sse2'/> <feature policy='force' name='sse4.1'/> <feature policy='force' name='sse4.2'/> <feature policy='force' name='ssse3'/> <feature policy='force' name='x2apic'/> </cpu> <clock offset='localtime'> <timer name='rtc' tickpolicy='catchup'/> </clock> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='qcow2' cache='none'/> <source file='/var/lib/libvirt/images/Server-10-9-13.qcow2'/> <target dev='vda' bus='virtio'/> <alias name='virtio-disk0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x08' function='0x0'/> </disk>

    Read the article

  • SCCM 2012 R2 - OSD Task Sequence failure on physical computers

    - by Svanste
    I'm trying to deploy windows 7 with SCCM 2012 R2 to physical desktops and laptops. But the task sequence keeps failing, no matter what I try. When I try it on a VM it works fine. However, when I try it on a physical computer it fails. So I think it has something to do with drivers, but I already tried both the "auto apply drivers" + wmi query for model method, and also the "apply driver package" + wmi query for model method. In the link below I added a zip file, containing two other zip files. One is a captured log from a failed osd on a desktop, the other is the export of my task sequence. Download zip-file with log and TS If anyone could resolve the issue, or share their own task sequence for such a task (pure sccm 2012 (R2), no MDT), that would be great.

    Read the article

  • SCCM 2012 R2 - OSD Task Sequence failure on physical computers

    - by user1422136
    I'm trying to deploy windows 7 with SCCM 2012 R2 to physical desktops and laptops. But the task sequence keeps failing, no matter what I try. When I try it on a VM it works fine. However, when I try it on a physical computer it fails. So I think it has something to do with drivers, but I already tried both the "auto apply drivers" + wmi query for model method, and also the "apply driver package" + wmi query for model method. In the link below I added a zip file, containing two other zip files. One is a captured log from a failed osd on a desktop, the other is the export of my task sequence. Download zip-file with log and TS If anyone could resolve the issue, or share their own task sequence for such a task (pure sccm 2012 (R2), no MDT), that would be great.

    Read the article

  • Performance difference between MacBook Pro (2.8 GHz) vs Air (1.7 GHz)?

    - by jonathanconway
    I'm comparing these two Apple laptops: MacBook Pro (13", 2011 model): 2.8GHz dual-core Intel Core i7 processor with 4MB shared L3 cache 4GB (two 2GB SO-DIMMs) of 1333MHz DDR3 SDRAM AMD Radeon HD 6770M graphics processor with 1GB of GDDR5 memory on 2.4GHz configuration MacBook Air (13", 2011 model): 1.7GHz dual-core Intel Core i5 with 3MB shared L3 cache 4GB of 1333MHz DDR3 onboard memory Intel HD Graphics 3000 processor with 384MB of DDR3 SDRAM shared with main memory There's definitely a gap between them in terms of CPU speed and graphics, but what practical difference would this make on a day-to-day basis? On the one hand, I love the sleek, thin appearance of the Air. On the other hand, I don't want a machine that's going to be dog-slow when doing tasks such as running Virtual Machines, dual-booting to Windows and running multiple instances of Visual Studio, and maybe some light gaming. Is there going to be a major difference that makes the MacBook Pro a more attractive purchase?

    Read the article

  • Digital audio input on Macbook?

    - by Ken
    I have: a Macbook (not Pro), don't know the exact model but it's a Core 2 Duo 2.0GHz and probably what Wikipedia calls the "Late 2006" or "Mid 2007" model a DVD player, region-free, that has "Coax and TosLink optical digital audio outputs" I want to make an MP3 of the audio track of some DVDs (for learning a new language), and I can't use the Macbook's built-in DVD drive because it's a different region (ugh!). I'm sure I can connect the DVD player to the Macbook with an analog audio cable. However, if it's possible I'd prefer to keep the signal digital. I'm not even positive if my old Macbook has digital audio in, and if so what I need to connect to it. (I've done plenty of home audio geeking, but always in analog!) Will a "Toslink cable" plus a "Toslink Female to Mini-Plug Male Adapter" (found on Amazon) let me connect my things together? It looks like the pieces will fit but I'd like to hear someone confidently knowledgeable on the matter before I buy something. Thanks!

    Read the article

  • Squid proxy in cent os often disconnected with error : tunnelConnectTimeout(): tunnelState->servers is NULL

    - by Ela
    I am having very often internet disconnection problem with Squid proxy service. My server config; OS: CentOS release 6.3 (Final) model name : Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz cpu MHz : 1600.000 My Local systems IP range:192.168.2.x Server IP: 192.168.2.11 Also this server is configured with lamp for development,Samba SMB file service manager and No svn currently. So i see maximum possibility is this squid proxy since this is where it stops to connect and am sure when i restart the server net started working so something wrong with this squid service only. And this server is connected with local 14 other windows machines and basically serves as a central development node. I am able to resolve it by restarting the server fully some time or sometimes by restarting the squid proxy which is totally killing our development. I have attached my cache log file here for the error info. Cache log file Sample error log: 2013/07/01 13:25:38| tunnelConnectTimeout(): tunnelState->servers is NULL 2013/07/01 13:25:41| tunnelConnectTimeout(): tunnelState->servers is NULL 2013/07/01 13:25:41| tunnelConnectTimeout(): tunnelState->servers is NULL 2013/07/01 13:25:50| clientProcessRequest: Invalid Request 2013/07/01 13:26:05| tunnelConnectTimeout(): tunnelState->servers is NULL Some help can make our lives easier, Thanks in advance.

    Read the article

  • How to record my voice on a Mac Mini with headphones?

    - by user718408
    I'm try to record my voice via the headphone on a Mac Mini, but it's not working. I saw on Apple's site that the Mac Mini can record voice, but it doesn't seem to be working for me. Here is a hardware overview: Model Name: Mac Mini Model Identifier: Macmini3,1 Processor Name: Intel Core 2 Duo Processor Speed: 2.26 GHz Number Of Processors: 1 Total Number Of Cores: 2 L2 Cache: 3 MB Memory: 4 GB Audio: Make: Intel High Definition Audio Audio ID: 65 Headphone connection: Combination Output Line Input connection: Combination Input Speaker connection: Internal S/PDIF Optical Digital Audio Output connection: Combination Output S/PDIF Optical Digital Audio Input connection: Combination Input Any ideas how I can successfully get recording working?

    Read the article

  • Is it possible to download minimal drivers on Windows, without the extra software packages?

    - by Anton Gogolev
    The situation in all its glory: 30 megs for ATIs' "Display Driver Only". Almost 100 megs for NVidias' GeForce/Ion bloatware. 300 megs for an HP printer driver with immense amount of crap 30 megs for a Realtek integrated sound card driver. 50 megs for a mouse driver ...and dozens and dozens of other similar examples Additinally, UI/UX on vendors' sites is really terrible: I have to carefully pick and choose the exact model of my whatever, although this packages do contain drivers for pretty much every possible hardware model out there. My question is: How and where can I download true minimal drivers without all these ATI "Installation Managers", Realtek GUIs, ASUS tools, etc.?

    Read the article

  • Why does my Mac always crash when I enable `ask for password after screensaver ended`?

    - by Koning Baard XIV
    I have enabled these two things: Placing the mouse-pointer in the bottom-left corner of any display makes the screensaver appear After the screensaver or stand-by has ended, ask for password However, this combination always leads to this (Black Screen of Death) after entering the screensaver with the bottom-left corner: Here are my system specs: Hardware Overview: Model Name: iMac Model Identifier: iMac9,1 Processor Name: Intel Core 2 Duo Processor Speed: 2,66 GHz Number Of Processors: 1 Total Number Of Cores: 2 L2 Cache: 6 MB Memory: 2 GB Bus Speed: 1,07 GHz Boot ROM Version: IM91.008D.B08 SMC Version (system): 1.44f0 Serial Number (system): W89171JF0TF Hardware UUID: 323A90F0-8A2F-5057-B501-2087489E0DFF System Software Overview: System Version: Mac OS X 10.6.3 (10D573) Kernel Version: Darwin 10.3.0 Boot Volume: Macintosh HD Boot Mode: Normal Computer Name: YOU SHOULD NOT KNOW THIS User Name: YOU SHOULD NOT KNOW THIS Secure Virtual Memory: Not Enabled 64-bit Kernel and Extensions: No Time since boot: 11:46 Can anyone help me? Thanks

    Read the article

  • ruby: invalid opcode

    - by adamo
    There's a fairly complex application than runs on two VMs (on Xen). Both VMs run CentOS 6.2 with the exact same packages and configuration for every application running (minus networking which is different). SELinux is disabled on both. On machine A the application builds perfectly. On machine B when running some tests we get: ruby[2010] trap invalid opcode ip:7ff9d2944c30 sp:7fff9797e0f8 error:0 in ld-2.12.so[7ff9d2930000+20000] Digging a bit more to find out where the machines differ, machine A has: model name : Six-Core AMD Opteron(tm) Processor 2423 HE and machine B: model name : AMD Opteron(TM) Processor 6272 I've tried booting machine B with cpuid_mask_cpu=fam_10_rev_c in grub but it did not help either. So any advice as to how to deal with this, or how to approach the hosting provider so as to run this VM on another physical machine will be greatly appreciated.

    Read the article

  • Laptop battery: is voltage really important to respect?

    - by Fox
    I got an Acer Aspire 5100 and I just bought a new battery (after the stock battery just died yesterday). But I saw something after buying and I'm wondering whether it's really important or not. My stock battery was a 6-cell 4000mah 11.1v and the new battery is an 8-cell 4800mah 14.8v . I know that 8-cell and 4800mah is okay, but what about the 14.8v instead of 11.1v? The battery description says it's compatible with my laptop model (AS5100, model BL51), but the voltage difference makes me wonder. Will the laptop only take what it needs? Or will it be getting 14.8v straight in the brain? I know that my wall plug claims to output 19v, so logically I'm thinking a higher voltage battery shouldn't be a problem. Am I correct in thinking this? Thanks in advance for your answers!

    Read the article

  • Which driver for "ATI Mobility Radeon HD 3650" in a laptop?

    - by Lasse V. Karlsen
    We have some HP laptops here that comes equipped with a video card that identifies itself as "ATI Mobility Radeon HD 3650", like this one. However, which drivers do we choose? As far as we can tell, HD 3650 is desktop cards, or at least there are no drivers listed for that series with "Mobility" in their name. If I pick the following on the ATI Driver Download page: Graphics Windows Vista 32-bit Edition Mobility Radeon Then the dropdown for the card model contains X300, X600, X700, X800, X1300, X1400, X1600, X1800, 9600, 9700 and 9800 models, but no "HD" nor "36xx series". However, if I change to just "Radeon" for the last selection there, I can find a "Radeon HD 3600 Series" model in the list. Also, if I pick "Windows 7" as the operating system, I can find a "Mobility Radeon HD 3000 series" card, but no 3600. So, which one to pick? The main reason I ask is that they all seem to have some kind of problem installing, so neither seems to be the right one (they all crash with "Catalyst Install Manager has stopped working".)

    Read the article

  • HP DL180 G6 P410 8x SATA 1TB, what is the optimal configuration?

    - by Oneiroi
    I have a HP DL180 G6 with a P410 raid controller. Presently this runs using 4x 1TB Samsung Spinpoint SATA drives, in a RAID10 configuration using default settings. I am about to add a backplane to increase the drive capacity from 4 to 12 drives, and I plan to install 4 more 1TB SATA Drives. The drives are matched and have close serial numbers (They arrived together in the Manufacturers pallet). Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s I will also be installing RHEL 6.1 x86_64. My question is what would be the optimal RAID settings (stripe etc.) for this configuration? To recap: 8x Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s RAID 10 configuration. Thanks in advance. Update for role: Server is to become an iscsi target for an internal openstack deployment currently underway. (Glance) Will also provide virtualisation through KVM

    Read the article

  • MySQL query, 2 similar servers, 2 minute difference in execution times

    - by mr12086
    I had a similar question on stack overflow, but it seems to be more server/mysql setup related than coding. The queries below all execute instantly on our development server where as they can take upto 2 minutes 20 seconds. The query execution time seems to be affected by home ambiguous the LIKE string's are. If they closely match a country that has few matches it will take less time, and if you use something like 'ge' for germany - it will take longer to execute. But this doesn't always work out like that, at times its quite erratic. Sending data appears to be the culprit but why and what does that mean. Also memory on production looks to be quite low (free memory)? Production: Intel Quad Xeon E3-1220 3.1GHz 4GB DDR3 2x 1TB SATA in RAID1 Network speed 100Mb Ubuntu Development Intel Core i3-2100, 2C/4T, 3.10GHz 500 GB SATA - No RAID 4GB DDR3 UPDATE 2 : mysqltuner output: [prod] -------- General Statistics -------------------------------------------------- [--] Skipped version check for MySQLTuner script [OK] Currently running supported MySQL version 5.1.61-0ubuntu0.10.04.1 [OK] Operating on 64-bit architecture -------- Storage Engine Statistics ------------------------------------------- [--] Status: +Archive -BDB -Federated +InnoDB -ISAM -NDBCluster [--] Data in MyISAM tables: 103M (Tables: 180) [--] Data in InnoDB tables: 491M (Tables: 19) [!!] Total fragmented tables: 38 -------- Security Recommendations ------------------------------------------- [OK] All database users have passwords assigned -------- Performance Metrics ------------------------------------------------- [--] Up for: 77d 4h 6m 1s (53M q [7.968 qps], 14M conn, TX: 87B, RX: 12B) [--] Reads / Writes: 98% / 2% [--] Total buffers: 58.0M global + 2.7M per thread (151 max threads) [OK] Maximum possible memory usage: 463.8M (11% of installed RAM) [OK] Slow queries: 0% (12K/53M) [OK] Highest usage of available connections: 22% (34/151) [OK] Key buffer size / total MyISAM indexes: 16.0M/10.6M [OK] Key buffer hit rate: 98.7% (162M cached / 2M reads) [OK] Query cache efficiency: 20.7% (7M cached / 36M selects) [!!] Query cache prunes per day: 3934 [OK] Sorts requiring temporary tables: 1% (3K temp sorts / 230K sorts) [!!] Joins performed without indexes: 71068 [OK] Temporary tables created on disk: 24% (3M on disk / 13M total) [OK] Thread cache hit rate: 99% (690 created / 14M connections) [!!] Table cache hit rate: 0% (64 open / 85M opened) [OK] Open file limit used: 12% (128/1K) [OK] Table locks acquired immediately: 99% (16M immediate / 16M locks) [!!] InnoDB data size / buffer pool: 491.9M/8.0M -------- Recommendations ----------------------------------------------------- General recommendations: Run OPTIMIZE TABLE to defragment tables for better performance Enable the slow query log to troubleshoot bad queries Adjust your join queries to always utilize indexes Increase table_cache gradually to avoid file descriptor limits Variables to adjust: query_cache_size (> 16M) join_buffer_size (> 128.0K, or always use indexes with joins) table_cache (> 64) innodb_buffer_pool_size (>= 491M) [dev] -------- General Statistics -------------------------------------------------- [--] Skipped version check for MySQLTuner script [OK] Currently running supported MySQL version 5.1.62-0ubuntu0.11.10.1 [!!] Switch to 64-bit OS - MySQL cannot currently use all of your RAM -------- Storage Engine Statistics ------------------------------------------- [--] Status: +Archive -BDB -Federated +InnoDB -ISAM -NDBCluster [--] Data in MyISAM tables: 185M (Tables: 632) [--] Data in InnoDB tables: 967M (Tables: 38) [!!] Total fragmented tables: 73 -------- Security Recommendations ------------------------------------------- [OK] All database users have passwords assigned -------- Performance Metrics ------------------------------------------------- [--] Up for: 1d 2h 26m 9s (5K q [0.058 qps], 1K conn, TX: 4M, RX: 1M) [--] Reads / Writes: 99% / 1% [--] Total buffers: 58.0M global + 2.7M per thread (151 max threads) [OK] Maximum possible memory usage: 463.8M (11% of installed RAM) [OK] Slow queries: 0% (0/5K) [OK] Highest usage of available connections: 1% (2/151) [OK] Key buffer size / total MyISAM indexes: 16.0M/18.6M [OK] Key buffer hit rate: 99.9% (60K cached / 36 reads) [OK] Query cache efficiency: 44.5% (1K cached / 2K selects) [OK] Query cache prunes per day: 0 [OK] Sorts requiring temporary tables: 0% (0 temp sorts / 44 sorts) [OK] Temporary tables created on disk: 24% (162 on disk / 666 total) [OK] Thread cache hit rate: 99% (2 created / 1K connections) [!!] Table cache hit rate: 1% (64 open / 4K opened) [OK] Open file limit used: 8% (88/1K) [OK] Table locks acquired immediately: 100% (1K immediate / 1K locks) [!!] InnoDB data size / buffer pool: 967.7M/8.0M -------- Recommendations ----------------------------------------------------- General recommendations: Run OPTIMIZE TABLE to defragment tables for better performance Enable the slow query log to troubleshoot bad queries Increase table_cache gradually to avoid file descriptor limits Variables to adjust: table_cache (> 64) innodb_buffer_pool_size (>= 967M) UPDATE 1: When testing the queries listed here there is usually no more than one other query taking place, and usually none. Because production is actually handling apache requests that development gets very few of as it's only myself and 1 other who accesses it - could the 4GB of RAM be getting exhausted by using the single machine for both apache and mysql server? Production: sudo hdparm -tT /dev/sda /dev/sda: Timing cached reads: 24872 MB in 2.00 seconds = 12450.72 MB/sec Timing buffered disk reads: 368 MB in 3.00 seconds = 122.49 MB/sec sudo hdparm -tT /dev/sdb /dev/sdb: Timing cached reads: 24786 MB in 2.00 seconds = 12407.22 MB/sec Timing buffered disk reads: 350 MB in 3.00 seconds = 116.53 MB/sec Server version(mysql + ubuntu versions): 5.1.61-0ubuntu0.10.04.1 Development: sudo hdparm -tT /dev/sda /dev/sda: Timing cached reads: 10632 MB in 2.00 seconds = 5319.40 MB/sec Timing buffered disk reads: 400 MB in 3.01 seconds = 132.85 MB/sec Server version(mysql + ubuntu versions): 5.1.62-0ubuntu0.11.10.1 ORIGINAL DATA : This query is NOT the query in question but is related so ill post it. SELECT f.form_question_has_answer_id FROM form_question_has_answer f INNER JOIN project_company_has_user p ON f.form_question_has_answer_user_id = p.project_company_has_user_user_id INNER JOIN company c ON p.project_company_has_user_company_id = c.company_id INNER JOIN project p2 ON p.project_company_has_user_project_id = p2.project_id INNER JOIN user u ON p.project_company_has_user_user_id = u.user_id INNER JOIN form f2 ON p.project_company_has_user_project_id = f2.form_project_id WHERE (f2.form_template_name = 'custom' AND p.project_company_has_user_garbage_collection = 0 AND p.project_company_has_user_project_id = '29') AND (LCASE(c.company_country) LIKE '%ge%' OR LCASE(c.company_country) LIKE '%abcde%') AND f.form_question_has_answer_form_id = '174' And the explain plan for the above query is, run on both dev and production produce the same plan. +----+-------------+-------+--------+----------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+-------------+ | id | select_type | table | type | possible_keys | key | key_len | ref | rows | Extra | +----+-------------+-------+--------+----------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+-------------+ | 1 | SIMPLE | p2 | const | PRIMARY | PRIMARY | 4 | const | 1 | Using index | | 1 | SIMPLE | f | ref | form_question_has_answer_form_id,form_question_has_answer_user_id | form_question_has_answer_form_id | 4 | const | 796 | Using where | | 1 | SIMPLE | u | eq_ref | PRIMARY | PRIMARY | 4 | new_klarents.f.form_question_has_answer_user_id | 1 | Using index | | 1 | SIMPLE | p | ref | project_company_has_user_unique_key,project_company_has_user_user_id,project_company_has_user_company_id,project_company_has_user_project_id | project_company_has_user_user_id | 4 | new_klarents.f.form_question_has_answer_user_id | 1 | Using where | | 1 | SIMPLE | f2 | ref | form_project_id | form_project_id | 4 | const | 15 | Using where | | 1 | SIMPLE | c | eq_ref | PRIMARY | PRIMARY | 4 | new_klarents.p.project_company_has_user_company_id | 1 | Using where | +----+-------------+-------+--------+----------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+-------------+ This query takes 2 minutes ~20 seconds to execute. The query that is ACTUALLY being run on the server is this one: SELECT COUNT(*) AS num_results FROM (SELECT f.form_question_has_answer_id FROM form_question_has_answer f INNER JOIN project_company_has_user p ON f.form_question_has_answer_user_id = p.project_company_has_user_user_id INNER JOIN company c ON p.project_company_has_user_company_id = c.company_id INNER JOIN project p2 ON p.project_company_has_user_project_id = p2.project_id INNER JOIN user u ON p.project_company_has_user_user_id = u.user_id INNER JOIN form f2 ON p.project_company_has_user_project_id = f2.form_project_id WHERE (f2.form_template_name = 'custom' AND p.project_company_has_user_garbage_collection = 0 AND p.project_company_has_user_project_id = '29') AND (LCASE(c.company_country) LIKE '%ge%' OR LCASE(c.company_country) LIKE '%abcde%') AND f.form_question_has_answer_form_id = '174' GROUP BY f.form_question_has_answer_id;) dctrn_count_query; With explain plans (again same on dev and production): +----+-------------+-------+--------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+------------------------------+ | id | select_type | table | type | possible_keys | key | key_len | ref | rows | Extra | +----+-------------+-------+--------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+------------------------------+ | 1 | PRIMARY | NULL | NULL | NULL | NULL | NULL | NULL | NULL | Select tables optimized away | | 2 | DERIVED | p2 | const | PRIMARY | PRIMARY | 4 | | 1 | Using index | | 2 | DERIVED | f | ref | form_question_has_answer_form_id,form_question_has_answer_user_id | form_question_has_answer_form_id | 4 | | 797 | Using where | | 2 | DERIVED | p | ref | project_company_has_user_unique_key,project_company_has_user_user_id,project_company_has_user_company_id,project_company_has_user_project_id,project_company_has_user_garbage_collection | project_company_has_user_user_id | 4 | new_klarents.f.form_question_has_answer_user_id | 1 | Using where | | 2 | DERIVED | f2 | ref | form_project_id | form_project_id | 4 | | 15 | Using where | | 2 | DERIVED | c | eq_ref | PRIMARY | PRIMARY | 4 | new_klarents.p.project_company_has_user_company_id | 1 | Using where | | 2 | DERIVED | u | eq_ref | PRIMARY | PRIMARY | 4 | new_klarents.p.project_company_has_user_user_id | 1 | Using where; Using index | +----+-------------+-------+--------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+----------------------------------+---------+----------------------------------------------------+------+------------------------------+ On the production server the information I have is as follows. Upon execution: +-------------+ | num_results | +-------------+ | 3 | +-------------+ 1 row in set (2 min 14.28 sec) Show profile: +--------------------------------+------------+ | Status | Duration | +--------------------------------+------------+ | starting | 0.000016 | | checking query cache for query | 0.000057 | | Opening tables | 0.004388 | | System lock | 0.000003 | | Table lock | 0.000036 | | init | 0.000030 | | optimizing | 0.000016 | | statistics | 0.000111 | | preparing | 0.000022 | | executing | 0.000004 | | Sorting result | 0.000002 | | Sending data | 136.213836 | | end | 0.000007 | | query end | 0.000002 | | freeing items | 0.004273 | | storing result in query cache | 0.000010 | | logging slow query | 0.000001 | | logging slow query | 0.000002 | | cleaning up | 0.000002 | +--------------------------------+------------+ On development the results are as follows. +-------------+ | num_results | +-------------+ | 3 | +-------------+ 1 row in set (0.08 sec) Again the profile for this query: +--------------------------------+----------+ | Status | Duration | +--------------------------------+----------+ | starting | 0.000022 | | checking query cache for query | 0.000148 | | Opening tables | 0.000025 | | System lock | 0.000008 | | Table lock | 0.000101 | | optimizing | 0.000035 | | statistics | 0.001019 | | preparing | 0.000047 | | executing | 0.000008 | | Sorting result | 0.000005 | | Sending data | 0.086565 | | init | 0.000015 | | optimizing | 0.000006 | | executing | 0.000020 | | end | 0.000004 | | query end | 0.000004 | | freeing items | 0.000028 | | storing result in query cache | 0.000005 | | removing tmp table | 0.000008 | | closing tables | 0.000008 | | logging slow query | 0.000002 | | cleaning up | 0.000005 | +--------------------------------+----------+ If i remove user and/or project innerjoins the query is reduced to 30s. Last bit of information I have: Mysqlserver and Apache are on the same box, there is only one box for production. Production output from top: before & after. top - 15:43:25 up 78 days, 12:11, 4 users, load average: 1.42, 0.99, 0.78 Tasks: 162 total, 2 running, 160 sleeping, 0 stopped, 0 zombie Cpu(s): 0.1%us, 50.4%sy, 0.0%ni, 49.5%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 4037868k total, 3772580k used, 265288k free, 243704k buffers Swap: 3905528k total, 265384k used, 3640144k free, 1207944k cached top - 15:44:31 up 78 days, 12:13, 4 users, load average: 1.94, 1.23, 0.87 Tasks: 160 total, 2 running, 157 sleeping, 0 stopped, 1 zombie Cpu(s): 0.2%us, 50.6%sy, 0.0%ni, 49.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 4037868k total, 3834300k used, 203568k free, 243736k buffers Swap: 3905528k total, 265384k used, 3640144k free, 1207804k cached But this isn't a good representation of production's normal status so here is a grab of it from today outside of executing the queries. top - 11:04:58 up 79 days, 7:33, 4 users, load average: 0.39, 0.58, 0.76 Tasks: 156 total, 1 running, 155 sleeping, 0 stopped, 0 zombie Cpu(s): 3.3%us, 2.8%sy, 0.0%ni, 93.9%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 4037868k total, 3676136k used, 361732k free, 271480k buffers Swap: 3905528k total, 268736k used, 3636792k free, 1063432k cached Development: This one doesn't change during or after. top - 15:47:07 up 110 days, 22:11, 7 users, load average: 0.17, 0.07, 0.06 Tasks: 210 total, 2 running, 208 sleeping, 0 stopped, 0 zombie Cpu(s): 0.1%us, 0.2%sy, 0.0%ni, 99.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 4111972k total, 1821100k used, 2290872k free, 238860k buffers Swap: 4183036k total, 66472k used, 4116564k free, 921072k cached

    Read the article

  • apcupsd on Linux does not report on APC BackUPS Pro 900

    - by lserni
    From what documentation I could find, the UPS should be (is!) supported by Linux and ought to work with apcupsd. I looked for specific problems such as the infamous Microlink protocol, and found none. I have found a feedback from a guy in UK that reports using this very model on a not-too-different OS version (his OpenSuSE 12.1, mine 12.3 x86_64). The USB port is detected, lsusb reports Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply and lsusb -v -s002:003 confirms and expands: Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x051d American Power Conversion idProduct 0x0002 Uninterruptible Power Supply bcdDevice 0.90 iManufacturer 1 American Power Conversion iProduct 2 Back-UPS RS 900G FW:879.L4 .I USB FW:L4 bNumConfigurations 1 Configuration Descriptor: [...] Interface Descriptor: [...] bInterfaceClass 3 Human Interface Device bInterfaceSubClass 0 No Subclass bInterfaceProtocol 0 None iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.00 bCountryCode 33 US bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 1134 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 100 Device Status: 0x0000 (Bus Powered) The kernel recognizes this and duly sets up crw------- 1 root root 180, 96 Nov 4 16:11 /dev/usb/hiddev0 As far as I know, everything is as it should be. I have put the standard configuration in /etc/apcupsd/apcupsd.conf (which is Unix-terminated, ASCII-only, no BOM (just in case)) UPSCABLE usb UPSTYPE usb DEVICE (I have also tried commenting out DEVICE, and setting a device of /dev/puppa results in an access attempt to /dev/puppa, not some /var/lib/dev/puppa or /dev/puppa\r\n). Yet, what apcaccess tells me is VERSION : 3.14.10 (13 September 2011) suse CABLE : USB Cable DRIVER : USB UPS Driver UPSMODE : Stand Alone STARTTIME: 2013-11-04 16:24:22 +0100 MODEL : STATUS : NOBATT LINEV : 000.0 Volts LOADPCT : 0.0 Percent Load Capacity BCHARGE : 000.0 Percent TIMELEFT : 0.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds SENSE : Low LOTRANS : 000.0 Volts HITRANS : 000.0 Volts It doesn't recognize the model, and reports no battery (and no voltage). This confirms that it's not the Microlink problem, or it would report the battery status, if precious little else. If I disconnect the USB cable, I get an apcupsd message to the effect that communications have been lost; and I get the "communication restored" broadcast too, if I reconnect the cable. apcupsd is monitoring. So everything tells me that it should work -- only it doesn't. Does anyone spot what I'm missing?

    Read the article

  • Cisco router for educational purposes

    - by user39214
    Hey all. I want to buy a Cisco router to use on my home network. I'm just hoping to get a unit that is not too old and is not a SOHO model. I want to run the latest Cisco OS just to learn how Cisco does things. I would use it to divide my network into two or three IP networks, firewalling, etc. I'm just asking for a model name/number. Thanks.