  • alias name in brocade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • How to get multipath working for Ubuntu Server 12.04

    - by mlampi
    I'm working on a project which aims to make use of Ubuntu servers running on enterprise class hardware. In our case that means IBM HS23E blade servers, QLogic 4GB fibre channel extension cards and quite old IBM DS4500 disk array with two controllers. At the moment we have fibre channel as only boot option and Ubuntu Server 12.04 installed just fine and is able to boot without multipath. I'm not a linux professional myself but in our team we have people who will understand the technical stuff. Don't let my post confuse :) The current situation is that we have only one fibre channel connection to a single disk array controller. Real life case would be of course quite different. At minimum we should have two fibre channel ports connected to two different switches and two different controllers. However, we have no idea how to set up multipath tool. Is the DM-MPIO the right software? At minimum we should be able to boot when multiple connections are available and achieve fault tolerance when any of them should be down. Since the disk array is not the latest hardware, I managed to find RDAC driver sources only for 2.6.x kernel. And we have 3.2.x. Another issue is to build a multipath.conf. The said driver sources are from IBM support and the QLogic drivers provided to Ubuntu installer are from Ubuntu site. It seems that RHEL and SLES would have near out of the box support but that is not an option for our project. Actual questions: - What is the recommended software tool for multipath for Ubuntu Server 12.04? - Is there available pre-made configurations or templates? Does it require disk array / controller specific settings or do a more generic config work? - Do you have expriences on similar setup and like to share the knowledge? I'll provide you with any additional information you might require. Thanks in advance.

    Read the article

  • What is good book for administration & configuration of Storage logical arrays?

    - by unknown (yahoo)
    I am looking for a book which can explain pros and cons of different combination of configurations/policies of storage Arrays and may also suggest some best practices for certain scenarios for e.g. when data availability & security is very important. There are a lot of "books for dummy" but they don't go in depth, I am a more of developer so I would like to understand how and why exactly it works beneath policies & configuration settings. I am working with EMC clarion logical array but I will have to work with EMC Symmetrix or NetApp or any other types of disk arrays.

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • Storage product testing

    - by wildchild
    hello, I know this is out of place (being an active member here i am coming for the help from seniors) ,but i need some information regarding storage testing ,testing of Raid arrays, SCSI, SAS ,SATA and also test carried out on fabric manager(Cisco MDS series switches). I am aware that this is an administrative forum and i would really appreciate if you could direct me to the correct forum ar links where i can learn things . @ moderators-Sorry for posting at the wrong place,i would be deleting this as soon as i get the help. Thanks !

    Read the article

  • Cannot login to ISCSI Target - hangs after sending login details

    - by Frank
    I have an ISCSI target volume, to which i am trying to connect using CentOS Linux server. Everything works fine, but cannot its stuck at login. Here are the steps i am performing: [root@neon ~]# iscsiadm -m node -l iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session20 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session21 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session22 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session23 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session30 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session31 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session78 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session79 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session80 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session81 Logging in to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) After this step, its stucks, waits for some time and then gives this output: Logging in to [iface: iface1, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) iscsiadm: Could not login to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260]. My iscsi.conf is this: node.startup = automatic node.session.timeo.replacement_timeout = 15 # default 120; RedHat recommended node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 5 node.session.err_timeo.abort_timeout = 15 node.session.err_timeo.lu_reset_timeout = 20 node.session.initial_login_retry_max = 8 # default 8; Dell recommended node.session.cmds_max = 1024 # default 128; Equallogic recommended node.session.queue_depth = 32 # default 32; Equallogic recommended node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 discovery.sendtargets.iscsi.MaxRecvDataSegmentLength = 32768 node.conn[0].iscsi.HeaderDigest = None node.session.iscsi.FastAbort = Yes Also, in access control, i have given full access to Any IP, Any CHAP user and fixed iscsi initiator name. With same access level, all other volumes on rest of servers are working, except this one.

    Read the article

  • Best practice Raid groups for EqualLogic PS6510X

    - by 20th Century Boy
    We are thinking about purchasing 4 x EqualLogic PS6510X SANs (the Sumo boxes). Each has 48 x 600GB 10k SAS drives. They will be stacked to form a logical pool of storage (all in the same location). I understand that when you create a RAID group its done on a "per box" basis. So one box could be Raid 50, another Raid 10 etc. My question is, should I make one box a "performance" box ie Raid 10, and the other boxes "standard" ie Raid50? How do people configure their EQL arrays in the real world?

    Read the article

  • Dell EqualLogic vs. EMC VNXe [closed]

    - by Untalented
    We've been looking into SMB SANs and based on the competitive pricing I've been getting we're really liking these two array's. There are some pro's to both solutions, but I've unable to really decide which to choose. The EMC offers better expandability since you can buy an additional shelf (roughly $1200) and can add drives then to the array. However, the Dell unit is still very nice. Can anyone comment on their experiences with the two and thoughts on this? Also, to get the VMware Storage API support you need VMware Enterprise. How much additional performance does this provide? It's roughly $15k more than the Essentials Plus bundle we're looking at (this is a small environment [3 Hosts 1 Array].

    Read the article

  • ESXi boot time with 9 iSCSI targets

    - by Myles Gray
    Our ESXi hosts have always been slow booting when it came to iscsi_vmk loaded successfully - sitting here for almost 5 minutes. In all a full server reboot takes almost 12 minutes. We have 9 iSCSI targets per host (5 SANs with redundant interfaces) configured as dynamic discovery targets. Has anyone experienced this? Can it be remedied with static discovery mode? Are there any debug steps we can work through to help diagnose this? (All our targets are accessible at boot so i'm assuming the host isn't stuck retrying to connect to a target)

    Read the article

  • Sparing level on HP EVA 4000

    - by Samuel
    One of the disks of our EVA4000 died today. This diskgroup (all volumes vraid5 with sparing level 1 and almost no space left for more volumes, 1TiB drives) is being rebuilt with "spare space" right now, and it will take at least 15 hours to do the leveling/rebuilding. We can't get a new disk until Friday. So, the question is, what would happen if another disk dies before the leveling completes? Would we lose data? And after that, how many aditional disks could die before losing data? 1 or 2? In "usual" RAID, we would be vulnerable to data loss while the rebuild takes place, but in this case the space reserved for sparing is two times the size of the bigger disk, so at the very least the effect should be the same of having two spares. Thanks in advance. Update: I have found some interesting threads about this question but still can't answer to this question, so I'm starting a bounty. http://blog.thestoragearchitect.com/2008/10/27/understanding-eva/ http://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&url=http%3A%2F%2Fwww.experts-exchange.com%2FStorage%2FStorage_Technology%2FQ_25548177.html (Expert Exchange question from google).

    Read the article

  • alias name in bracade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

  • Host not visible in ECC after pushing master agent on server

    - by wildchild
    Hi all!! ECC master Agent has been pushed to one of the servers.. Once a Master Agent installed the host should appear within ECC.However, I am unable to see the host. I asked the Server team to stop and start the master agent ,and to check whether required port is enabled, so that server can talk with ECC server. After restarting the service I get an error.I even checked if the port is used by any other service ,it is not.. Somebody plz help what should done here..it’s a Windows server. Here's the error:- "The EMC control Center Master agent service on local computer atrted and the stopped.Some services stopped automatically if they 've no work to do,for example prformance logs and alert services" Thanks in advance!!

    Read the article

  • V MAX Anyone..Need to learn administrating VMAX

    - by kevinmika
    Hello All, This is going to be my first post here. I 'm working as an Administrator at SNI. I have been responsible for managing Celerra and Clariion,but this new environment has 2 VMAX boxes . Since, I don't have prior experience is managing symmetrix ,i am kinda stuck here ( no training as well) Can some body suggest me a proper link where i can learn the basics as well as the administrative part of V MAX. Thanks in advance for your help! Kevin

    Read the article

  • How do I resolve an "Invalid Transaction" error saving a zone config in Brocade Web Tools?

    - by Frank Szczerba
    When trying to save zoning changes in the Zone Administration tool in Brocade Web Tools, I get the status "Failed to commit changes to fabric" and the messages window shows: --- start of commit (Enable Config) at: Fri Jul 23 2010 19:43:40 GMT+00:00 Invalid Transaction --- end of commit at: Fri Jul 23 2010 19:43:47 GMT+00:00 I've tried refreshing the config and just re-saving what is already on the switch, but can't get this message to go away.

    Read the article

  • Areca 1880ix RAID hangs

    - by Dave
    Areca RAID controller ARC-1880ix-12 (firmware 1.50) hangs when on high load. My setup is: Chenbro 3U chassis Intel S5500BC mainboard Xeon 5603 CPU 16GB of RAM 12 Seagate SAS drives ST32000645SS (2 of them as hot spare, 10 as RAID10) Mellanox Infiniband HBA card This server is working as external infiniband storage for Xen VMs. When load is quite big Areca's firmware hangs - it becomes unreachable even from Areca's ethernet adapter. After resetting the server power it returns to normal operation. While Areca is hanged I can confirm that it is powered (ethernet link is active) and Infiniband HBA works Ok. Thanks in advance for any idea or suggestion where the problem might be!

    Read the article

  • Page allocation failures on iSCSI storage

    - by Dave
    We have a CentOS 6.3 iscsi server (16GB RAM) running on Infiniband bus (ipoib). When the load is high I can see multiple errors: Sep 3 23:22:20 stor4 kernel: tgtd: page allocation failure. order:2, mode:0x20 Sep 3 23:22:20 stor4 kernel: Pid: 3637, comm: tgtd Not tainted 2.6.32 #1 Sep 3 23:22:20 stor4 kernel: Call Trace: Sep 3 23:22:20 stor4 kernel: [] ? __alloc_pages_nodemask+0x77f/0x940 Sep 3 23:22:20 stor4 kernel: [] ? kmem_getpages+0x62/0x170 Sep 3 23:22:20 stor4 kernel: [] ? fallback_alloc+0x1ba/0x270 Sep 3 23:22:20 stor4 kernel: [] ? cache_grow+0x2cf/0x320 Sep 3 23:22:20 stor4 kernel: [] ? ____cache_alloc_node+0x99/0x160 Sep 3 23:22:20 stor4 kernel: [] ? pskb_expand_head+0x64/0x270 Sep 3 23:22:20 stor4 kernel: [] ? __kmalloc+0x189/0x220 Sep 3 23:22:20 stor4 kernel: [] ? pskb_expand_head+0x64/0x270 Sep 3 23:22:20 stor4 kernel: [] ? __pskb_pull_tail+0x2aa/0x360 Sep 3 23:22:20 stor4 kernel: [] ? tcp_init_tso_segs+0x37/0x50 Sep 3 23:22:20 stor4 kernel: [] ? dev_queue_xmit+0x4bb/0x6f0 Sep 3 23:22:20 stor4 kernel: [] ? neigh_connected_output+0xbd/0x100 Sep 3 23:22:20 stor4 kernel: [] ? ip_finish_output+0x237/0x310 Sep 3 23:22:20 stor4 kernel: [] ? ip_output+0xb8/0xc0 Sep 3 23:22:20 stor4 kernel: [] ? __ip_local_out+0x9f/0xb0 Sep 3 23:22:20 stor4 kernel: [] ? ip_local_out+0x25/0x30 Sep 3 23:22:20 stor4 kernel: [] ? ip_queue_xmit+0x190/0x420 Sep 3 23:22:20 stor4 kernel: [] ? sock_aio_write+0x167/0x180 Sep 3 23:22:20 stor4 kernel: [] ? tcp_transmit_skb+0x3fe/0x7b0 Sep 3 23:22:20 stor4 kernel: [] ? tcp_write_xmit+0x1fb/0xa20 Sep 3 23:22:20 stor4 kernel: [] ? __tcp_push_pending_frames+0x30/0xe0 Sep 3 23:22:20 stor4 kernel: [] ? tcp_push_pending_frames+0x33/0x40 Sep 3 23:22:20 stor4 kernel: [] ? do_tcp_setsockopt+0x3d6/0x480 Sep 3 23:22:20 stor4 kernel: [] ? tcp_setsockopt+0x2a/0x30 Sep 3 23:22:20 stor4 kernel: [] ? sock_common_setsockopt+0x14/0x20 Sep 3 23:22:20 stor4 kernel: [] ? sys_setsockopt+0x7f/0xe0 Sep 3 23:22:20 stor4 kernel: [] ? system_call_fastpath+0x16/0x1b Sep 3 23:22:20 stor4 kernel: Mem-Info: Sep 3 23:22:20 stor4 kernel: Node 0 DMA per-cpu: Sep 3 23:22:20 stor4 kernel: CPU 0: hi: 0, btch: 1 usd: 0 Sep 3 23:22:20 stor4 kernel: CPU 1: hi: 0, btch: 1 usd: 0 Sep 3 23:22:20 stor4 kernel: CPU 2: hi: 0, btch: 1 usd: 0 Sep 3 23:22:20 stor4 kernel: CPU 3: hi: 0, btch: 1 usd: 0 Sep 3 23:22:20 stor4 kernel: Node 0 DMA32 per-cpu: Sep 3 23:22:20 stor4 kernel: CPU 0: hi: 186, btch: 31 usd: 183 Sep 3 23:22:20 stor4 kernel: CPU 1: hi: 186, btch: 31 usd: 23 Sep 3 23:22:20 stor4 kernel: CPU 2: hi: 186, btch: 31 usd: 183 Sep 3 23:22:20 stor4 kernel: CPU 3: hi: 186, btch: 31 usd: 181 Sep 3 23:22:20 stor4 kernel: Node 0 Normal per-cpu: Sep 3 23:22:20 stor4 kernel: CPU 0: hi: 186, btch: 31 usd: 171 Sep 3 23:22:20 stor4 kernel: CPU 1: hi: 186, btch: 31 usd: 29 Sep 3 23:22:20 stor4 kernel: CPU 2: hi: 186, btch: 31 usd: 32 Sep 3 23:22:20 stor4 kernel: CPU 3: hi: 186, btch: 31 usd: 32 Sep 3 23:22:20 stor4 kernel: active_anon:1875 inactive_anon:2473 isolated_anon:0 Sep 3 23:22:20 stor4 kernel: active_file:1243637 inactive_file:2505055 isolated_file:0 Sep 3 23:22:20 stor4 kernel: unevictable:0 dirty:268338 writeback:0 unstable:0 Sep 3 23:22:20 stor4 kernel: free:86050 slab_reclaimable:132377 slab_unreclaimable:23744 Sep 3 23:22:20 stor4 kernel: mapped:1293 shmem:222 pagetables:720 bounce:0 Sep 3 23:22:20 stor4 kernel: Node 0 DMA free:15732kB min:124kB low:152kB high:184kB active_anon:0kB inactive_anon:0kB active_file:0kB inactive_file:0kB unevictable:0kB isolated(anon):0kB isolated(file):0kB present:15332kB mlocked:0kB dirty:0kB writeback:0kB mapped:0kB shmem:0kB slab_reclaimable:0kB slab_unreclaimable:0kB kernel_stack:0kB pagetables:0kB unstable:0kB bounce:0kB writeback_tmp:0kB pages_scanned:0 all_unreclaimable? yes Sep 3 23:22:20 stor4 kernel: lowmem_reserve[]: 0 2172 16060 16060 Sep 3 23:22:20 stor4 kernel: Node 0 DMA32 free:107544kB min:18268kB low:22832kB high:27400kB active_anon:468kB inactive_anon:2364kB active_file:566208kB inactive_file:976112kB unevictable:0kB isolated(anon):0kB isolated(file):0kB present:2224900kB mlocked:0kB dirty:96816kB writeback:0kB mapped:908kB shmem:12kB slab_reclaimable:176940kB slab_unreclaimable:968kB kernel_stack:64kB pagetables:192kB unstable:0kB bounce:0kB writeback_tmp:0kB pages_scanned:0 all_unreclaimable? no Sep 3 23:22:20 stor4 kernel: lowmem_reserve[]: 0 0 13887 13887 Sep 3 23:22:20 stor4 kernel: Node 0 Normal free:220924kB min:116772kB low:145964kB high:175156kB active_anon:7032kB inactive_anon:7528kB active_file:4408340kB inactive_file:9044108kB unevictable:0kB isolated(anon):0kB isolated(file):0kB present:14220800kB mlocked:0kB dirty:976536kB writeback:0kB mapped:4264kB shmem:876kB slab_reclaimable:352568kB slab_unreclaimable:94008kB kernel_stack:2048kB pagetables:2688kB unstable:0kB bounce:0kB writeback_tmp:0kB pages_scanned:0 all_unreclaimable? no Sep 3 23:22:20 stor4 kernel: lowmem_reserve[]: 0 0 0 0 Sep 3 23:22:20 stor4 kernel: Node 0 DMA: 1*4kB 0*8kB 1*16kB 1*32kB 1*64kB 0*128kB 1*256kB 0*512kB 1*1024kB 1*2048kB 3*4096kB = 15732kB Sep 3 23:22:20 stor4 kernel: Node 0 DMA32: 16305*4kB 4381*8kB 353*16kB 8*32kB 1*64kB 1*128kB 0*256kB 1*512kB 1*1024kB 0*2048kB 0*4096kB = 107900kB Sep 3 23:22:20 stor4 kernel: Node 0 Normal: 14548*4kB 14808*8kB 2420*16kB 31*32kB 5*64kB 0*128kB 0*256kB 0*512kB 0*1024kB 0*2048kB 1*4096kB = 220784kB Sep 3 23:22:20 stor4 kernel: 3748822 total pagecache pages Sep 3 23:22:20 stor4 kernel: 0 pages in swap cache Sep 3 23:22:20 stor4 kernel: Swap cache stats: add 0, delete 0, find 0/0 Sep 3 23:22:20 stor4 kernel: Free swap = 975864kB Sep 3 23:22:20 stor4 kernel: Total swap = 975864kB Sep 3 23:22:20 stor4 kernel: 4194303 pages RAM Sep 3 23:22:20 stor4 kernel: 126915 pages reserved Sep 3 23:22:20 stor4 kernel: 3753534 pages shared Sep 3 23:22:20 stor4 kernel: 213500 pages non-shared TCP stack and VM config: net.core.rmem_max = 83886080 net.core.wmem_max = 83886080 net.core.rmem_default = 65536 net.core.wmem_default = 65536 net.ipv4.tcp_rmem = 40960 1048560 4194304 net.ipv4.tcp_wmem = 40960 196608 4194304 net.ipv4.tcp_mem = 16388608 16388608 16388608 vm.min_free_kbytes=135168 Additional tweaks: /sbin/blockdev --setra 16384 /dev/sdb echo 2048 /sys/block/sdb/queue/nr_requests Where might the problem be? Thank you.

    Read the article

  • EMC CX3-10c Fault Condition won;t clear

    - by ITGuy24
    We have an old CX3-10c from Dell that had both Standby Power Supplies (SPS) fail. This obviously caused a fault on the system and disabled the cache. We have replaced the SPS's and they test fine as do all other components. Problem is there is still a fault on the "Enclosure SPE [SPE3]" despite all the component in the enclosure showing as good. I was on the line with Dell Gold support for 3 hours yesterday, they have had me restart the SPs multiple times, as well as reseat the power supplies, even shutdown the system completely and power it back on. All to no avail. Fault remains and cache cannot be re-enabled so long as the Fault is present. Any suggestions on clearing this erroneous fault?

    Read the article

  • Luns not taken by the windows server admin

    - by wildchild
    I have a scenario based question...Something , I haven't faced till now ,but i would be interested to know the answer. If i have assigned a luns (say, of 50 GB) and put them in storage group.However, the windows server team did not grab that lun but sent an acknowledgment saying the Luns are alingned. I would like to know what will happen to the Luns that belong to the SG ..in my opinion they will remain in the SG as unassigned Luns ..or is there a possibility that the lUns will move back to the storage.

    Read the article

  • Splitting Multiple Files in Windows

    - by Justin Boucher
    We have a 21TB LUN full of images that are approx 600K in size in multiple sub folders on the disk. We are trying to split the 21TB LUN into 8 smaller LUNs that are about 2.6TB a piece in order to process the images more effectively. My question is how we can determine what 2.6TB is on the drive? What is the best tool to mark this data so we can copy it to the new smaller LUNs with robocopy or emcopy without overfilling the smaller LUNs? Is there a third-party tool that would be better suited for this task? Thank you in advance for your assistance.

    Read the article

  • what NAS cellera services to be monitered?

    - by wildchild
    We have a monitoring tool called SCOM which mainly monitors different OS related services .However, we being part of storage team would also like some of our services to be monitored. We have HP NAS , and I am wondering what all services I can ask the other team to monitor for us and alert us if something goes wrong. The same goes with celerra and centera what important services can be monitored .I did search but to no avail.I ‘m not finding any of the useful services..Any help in this regard is greatly appreaciated thanks!