Search Results

Search found 906 results on 37 pages for 'rebuild'.

Page 25/37 | < Previous Page | 21 22 23 24 25 26 27 28 29 30 31 32  | Next Page >

  • Problems migrating software RAID 5 to new server (linux)

    - by leleu
    I have a CentOS setup with sw RAID5 that holds my data. Well, the server died, so I bought another box to migrate my drives to. Only thing is, I cannot get the RAID array rebuilt (not even sure it needs rebuilding, might just need the /dev/md0 mapping created... but I don't even know how to determine what I need!) Some details: RAID5 software (used mdadm) 4x 250GB drives (2 are SATA, 2 are EIDE -- would this matter? It worked fine in the other box...) latest CentOS distro built using mdadm I've got a decent amount of experience with standard linux stuff, but the hardware level stuff runs me in circles. I've spent some time googling and elsewhere here on SF, so please be kind for my newbie questions :). My question is this: how can I diagnose the problem? For all I know, I'm using the wrong device blocks when I try to rebuild the array, but I can't find the command to display only the devices that have some physical attachment. Is there some simple way for me to run mdadm, having it scan over all my physical drives, and say "hey, drives 2,5,6,7 are a software array, want me to mount it?" I basically just took the drives from my old box and put it into my new one. They show up in the BIOS. What steps do I need to take in order to get the array up, running, and mounted? Thanks in advance!

    Read the article

  • raid md device is not remove from memory, how to overcome this problem

    - by santhosha
    i create raid 10 , i removed two arrays form md11 one by one , after that i going to editing the contents those are mounted ( it will be not responding stage), after i try for remove arrays those are left it is shows device or resource busy ( is not removed from memory). i try to terminate process this is also not work, i absorve from 4 days resync will be 8.0% it can not modifying. cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec mdadm -D /dev/md11 /dev/md11: Version : 00.90.03 Creation Time : Sun Jan 16 16:20:01 2011 Raid Level : raid10 Array Size : 286743936 (273.46 GiB 293.63 GB) Device Size : 143371968 (136.73 GiB 146.81 GB) Raid Devices : 4 Total Devices : 2 Preferred Minor : 11 Persistence : Superblock is persistent Update Time : Sun Jan 16 16:56:07 2011 State : active, degraded, resyncing Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K Rebuild Status : 8% complete UUID : 5e124ea4:79a01181:dc4110d3:a48576ea Events : 0.23 Number Major Minor RaidDevice State 0 0 0 0 removed 1 0 0 1 removed 4 8 145 2 faulty spare rebuilding /dev/sdj1 3 8 65 3 active sync /dev/sde1 umount /dev/md11 umount: /dev/md11: not mounted mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 kill -9 2128 kill -9 5018 kill -9 27605 kill -9 30562 kill -3 30591 mdadm -S /dev/md11 mdadm: fail to stop array /dev/md11: Device or resource busy lsof /dev/md11 COMMAND PID USER FD TYPE DEVICE SIZE NODE NAME mount 2128 root 3r BLK 9,11 4058 /dev/md11 mount 5018 root 3r BLK 9,11 4058 /dev/md11 mdadm 27605 root 3r BLK 9,11 4058 /dev/md11 mount 30562 root 3r BLK 9,11 4058 /dev/md11 badblocks 30591 root 3r BLK 9,11 4058 /dev/md11 cat /proc/mdstat Personalities : [raid1] [raid0] [raid6] [raid5] [raid4] [linear] [raid10] md11 : active raid10 sde1[3] sdj14 286743936 blocks 64K chunks 2 near-copies [4/1] [___U] [1:2:3:0] [=...................] resync = 8.0% (23210368/286743936) finish=289392.6min speed=15K/sec

    Read the article

  • External Hard Drive Won't Mount - MAC OSX

    - by dtj
    I have a Western Digital hard drive that's about 4 or 5 years old. It's 500 GB, USB. I use it to backup my Mac every so often. I had it partitioned: 1 side for full backups, and the other side for general storage of music, installers, etc. I decided to get rid of the partition today and dump all the data. So I opened disk utility, and hit 'erase'. It started thinking and then disk utility crashed. After the crash, the hard drive won't mount, however disk utility still sees the drive, but not the individual volume within. I tried booting up Disk Warrior and no luck there either. It has the drive as an "unknown drive". When I hit rebuild, it goes through all it steps and then stops cause of this error: The drive "unknown" is severely damaged and DiskWarrior is unable to determine its case sensitivity What can I do at this point? There isn't any physical damage to the drive. Never been dropped or anything.

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • Outlook 2007 OST File Indexing and OneNote 2007 Indexing are Broken

    - by Matt
    I'm running Outlook 2007 under Windows 7 Home Premium RTM. My OST file was previously being properly indexed but eventually searches significantly slowed down so I suspected a problem. Searching and indexing appears broken in OneNote 2007 as well as search time is now significantly longer. I brought up the Outlook 2007 Search Options dialog and noticed that my mailbox (running from an Exchange 2007 server) wasn't listed in the "Index messages in these data files:" list box. Next I ran the Windows "Find and fix problem with windows search" wizard which reported no errors. Then I brought up the Windows Indexing Options dialog which shows Outlook listed (as shown here): then clicked Advanced and Rebuilt the index. No dice - the listbox in the Outlook 2007 dialog still didn't show my mailbox. When I clicked the Modify button in the Indexing Options dialog I see the following: When I hover over the "oneindex://..." entry, the alt text indicates "This location is currently unavailable". When I delete it and rebuild the index, this entry returns. UPDATE: Comparison of the last screenshot above with a working PC shows that on the broken PC, the lower half of the dialog lists Outlook but neither Outlook or OneNote are showing in the upper half. The working PC has Outlook and OneNote in both parts of the dialog.

    Read the article

  • BOOTMGR is compressed

    - by JavaAndCSharp
    So I've just finished messing up my computer beyond repair. I originally had a Windows 7 install on my 64GB SSD and all my data on my 1.5TB HDD. So I decided to install Windows 8 Consumer Preview. I tried to clone my 64GB SSD onto my HDD; but that didn't work either at first. I later learned that it wiped all my data off of it. Thank goodness for the cloud. So I retried the cloning after I realized that my data was gone, and I finished it. So I rebooted and got a cryptic error message: BOOTMGR is compressed. Press Ctrl+Alt+Del to restart. So I did. Several times. I followed the instructions to rebuild the bootmanager from many websites, including HowToGeek, smallvoid.com, and more. None worked. BTW, I've lost my Windows 7 Professional DVDs. All I have is my Windows 7 Home Premium DVD. It's the one I got with my laptop. How can I get back to a working computer? I'm willing to wipe anything, as my data is all in the cloud.

    Read the article

  • Solaris 10 zlogin logs in, logs out immediately

    - by Spelevink
    On a SPARC v445 running Solaris 10 9/10, had to rebuild rpool and reattached the three existing mirrored zpools on the other existing disks, with their zfs filesystems and NG zones intact. The zones have been configured with zonecfg -z ZONENAME create etc. ... and are now online using zoneadm -z ZONENAME attach -U then simply booting after being in installed state, but I cannot zlogin to any of the zones except one. It shows that I am logged in, then a blank line, then immediately logged out again. When I try to login using zlogin -C ZONENAME I cannot; the error message is: May 15 15:43:46 <hostname> login: open_module: stat(/usr/lib/security/pam_mkhomedir.so.1) failed: no such file or directory. May 15 15:43:46 <hostname> login: load_modules: cannot open module /usr/lib/security/pam_mkhomedir.so.1 But /usr/lib/pam_mkhomedir.so.1 does not exist, and it does not exist on my other servers, but those zones are accessible using zlogin. I can only zlogin to the zones with zlogin -S ZONENAME. What to do next? Thank you.

    Read the article

  • NGINX SSI Not working

    - by Mike Kelly
    I'm having trouble getting SSI to work on NGINX. You can see the problem if you hit http://www.bakerycamp.com/test.shtml. Here is the contents of that file: <!--# echo hi --> If you hit this in a browser, you see the SSI directive in the content - so apparently NGINX is not interpreting the SSI directive. My NGINX config file looks like this: server { listen 80; server_name bakerycamp.com www.bakerycamp.com; access_log /var/log/nginx/bakerycamp.access.log; index index.html; root /home/bakerycamp.com; location / { ssi on; } # Deny access to all hidden files and folders location ~ /\. { access_log off; log_not_found off; deny all; } } I did not build NGINX from sources but installed it using apt-get. I assume it has the SSI module (since that is default) but perhaps not? Should I just bite the bullet and rebuild from sources? Is there anyway to tell if the installed NGINX supports SSI and my config is just wrong?

    Read the article

  • MAC addresses on dual-NIC mainboards

    - by Tom O'Connor
    Here's a weird problem. We've got a number of devices with dual-NIC mainboards. Some are Realtek NICs, which suck. Some are Intel e1000s, which don't. I've just noticed on 2 machines, one is an Intel NIC, one is a Realtek, that when I put the MAC address of one machine into the dhcpd.conf file on our DHCP server to get it to PXE boot the machine into a rebuild environment, initially everything is fine. The server gets a DHCP allocation, and PXE boots into the Ubuntu preseed enviroment. On one or two machines, it gets as far as Ubuntu's DHCP network configuration, and fails. If i pull up a busybox shell (on tty2 on the installing machine), and run ip link, I can see that the UP flag is set on the other NIC. Here's some stuff. host xeon16-ghz240-gb48-node1 { hardware ethernet BC:AE:C5:07:1F:18; filename "pxelinux.0"; next-server 192.168.123.80; } That's what's in dhcpd.conf This is what ip link on the evil machine looks like. Only one NIC is actually connected (deliberately). As you can see, the NIC that's in the dhcpd config, is not marked as UP, and the link that is UP, isn't the one in DHCP. So far I've seen this on two brands of dual-NIC configuration. Does anyone know 1) what's causing it, and b) What we can do about it?

    Read the article

  • ESXi 4.0 Guests Locking up

    - by Brendan Sherwin
    I installed ESXi 4.0 on an HP Proliant g5 with a 64bit Xeon processor and took advantage of the free license as I work for a public school. I created two instances of server 2003 from scratch, one to be the DC, DHCP, the other to be a file server and DNS/DHCP backup. I had both guests up and running fine, setup my user accounts, transferred the data, etc etc. Once I joined a client machine to the domain, I would find that both of my Windows guests would lock up. Sometimes it would be for five or so minutes, once it was overnight. The "locked up" state means that as far I could tell, all services were stopped; dhcp no longer handed out IP's, DNS stopped working, I couldn't RDP into the server. The ESXi host, my HP server, was still running fine. VSphere was working, and I could look at the performance of the individual guests.I would try Powering off the hosts from inside VSPhere, and the hosts would start powering off, but get stuck at 95%, and stay that way, sometimes only for 10 minutes, others for hours. Several times I had to restart ESXi from it's console in order to restart my machines. Now, can anyone tell me what is happening, and how I can fix it, or take steps to prevent it? I hired a consultant to come take a look at it, someone who's experience and knowledge I trust, and he told me he had never seen anything like this ever before. He spoke to a friend of his who is VM certified, and he also said he had never heard of this issue. Thanks for your replies, and I'll do my best to respond ASAP. Currently, the server is powered off, and I've reinstituted my nine year old Server 2000 boxes, and I'm considering installing ESXi 3.5. Does anyone know a host created in 4.0 will work in 3.5? I'd really like to avoid having to rebuild those accounts! I know 4.0 works on this server, as I have another server in another school with the same exact hardware running 4.0 fine. Brendan

    Read the article

  • Reboot fails with "Invalid partition"

    - by Mike Clark
    My laptop can't reboot. Any time something restarts the laptop (e.g. to apply Windows updates, or Start Menu-Restart, etc), the computer sits at a black screen with the message "Invalid partition" displayed in console text. When this happens, I power off the computer, then power it back on, and it boots up fine. OK, now the history behind this: This laptop is a new Dell. The day I got it, I used gparted to reclaim 30 GB of disk space that had been allocated to a "recovery partition" in the middle of the laptop's primary drive. (I have DVDs for recovery and I didn't want to waste 30 GB of SSD space on recovery data.) So I used gparted to delete the recovery partition and resize the primary Windows partition to use up the new free space. As expected when resizing a boot partition, the computer would no longer boot. I used Windows Recovery Console to fix the boot process: FIXMBR C: FIXBOOT C: BOOTCFG /rebuild This worked fine and the computer boots up fine. But, as mentioned earlier, the laptop still can't reboot. Any idea on how to fix this without completely reformatting the disk and reinstalling Windows from scratch? It's Windows 7.

    Read the article

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Kickstart installation from USB -- Kickstart location

    - by dooffas
    After managing to get a Fedora ISO to rebuild successfully (for a USB stick) after adding a kickstart file (http://serverfault.com/questions/548405/), I now have an issue with locating the kickstart file on the USB media. When this is done from a CDROM you can simply kickckstart by adding this parameter to boot: linux ks=cdrom This will kickstart (providing the kickstart file is named ks.cfg and is in the root of the disk). Now, obviously this will be different for the USB drive, so from my research, I assumed that this line would do the job: linux ks=hd:sdb1:/ks.cfg Evidently this does not work. I get an error informing me this drive is already mounted and cannot be remounted. EDIT: Actual error message: mount: /dev/sdb1 is already mounted or /run/install/tmpmnt0 busy Warning: Can't get kickstart from /dev/sdb1:/ks.cfg To test that the syntax was correct I placed the kickstart file on another USB stick and loaded the same command to grab ks.cfg from the new location: linux ks=hd:sdc1:/ks.cfg This does work (providing USB sticks are mounted in order, boot - sdb1, kickstart - sdc1). The install will kickstart and complete the install with no issue. Obviously having to use 2 pen drives is somewhat frustrating and unreliable. Is there a way around this?

    Read the article

  • Backup, Migrate or Clone Failing CentOS 4 (LVM)

    - by Hegelworm
    Hello there, I've been running a BlueQuartz CentOS 4 system (Nuonce.net distro) for a few years now and although the hard drive (Deskstar) has always been a bit noisy, on a few recent occasions I've heard it having trouble spinning up. Basically, I want to clone this drive to a similar sized one (80 Gig). I've spent many hours reading upon dd, dd_rescue, rsync, clonezilla and LVM mirroring yet the sheer number of options and nightmarish accounts has left me frozen - unable to make an informed decision as to how to start. I've made a few attempts. dd failed after about 2 hours, as, although the drives appeared to be identical on the surface (ATA Seagate Barracudas, Thai not Chinese), the destination drive is slightly smaller. My most recent attempt involved using a Debian CD to format the new drive and then rsync-ing everything over and editing the new drive's grub and fstab to reflect the changes. No joy here either as I hadn't chosen LVM when partitioning the destination drive and it wouldn't boot. As you can probably tell, I'm out of my depth here and a panic-invoking mixture of caution and frustration has prompted me to sign up here. The server itself, although not strictly a production environment, has a very specific installation of Festival, LAME and ffMpeg and provides the back-end for a Text-to-Speech jQuery plugin that I've built over the last 2 years. I'm also planning to rebuild the whole TTS system on Debian as the existing CentOS system still has PHP4 etc. For now though, I'd really like to just shift everything over to a new drive. As this is my first post, please feel free to lay any house rules on me that I might've overlooked; I've been hovering around StackOverflow for a while now but have only just signed up. Many thanks.

    Read the article

  • Reinserted a RAID disk. Defined as foreign. Is import or clear the correct choice?

    - by Petrus
    I have re-inserted a RAID disk, on a DELL server with Windows Server 2008. The drive-status indicator was changing between a green and amber light, and the monitor gave the following message: There are offline or missing virtual drives with preserved cache. Please check the cables and ensure that all drives are present. Press any key to enter the configuration utility. I pressed a key and the PERC 6/I Integrated BIOS Configuration Utility showed that the RAID Status for that disk was Offline. After reinsertion of the disk the monitor is giving the following message: Foreign configuration(s) found on adapter. Press any key to continue or ‘C’ load the configuration utility, or press ‘F’ to import foreign configuration(s) and continue. After checking around on the net I am uncertain if I should choose import or clear. I cannot find out if an import means importing information from the array/system to the now foreign disk or the other way, i.e. importing information from the foreign disk to the array/system that was actually working fine. Also; if clear is a necessary thing to do ahead of a rebuild of that disk, or if clear means to clear the system to somehow make it ready to import the information from the foreign disk to the array/system, which is not what I want. I imagine that making the wrong choice here might be fatal. Please help clearing this out by telling what to choose and why.

    Read the article

  • Looking for a comprehensive/"expert" guide to BCD parameters

    - by Stilez
    I'm interested in educating myself about BCD on Windows 8. There are many, many "walkthrough" guides" and "howtos", but I can't find any guides at typical "enthusiast" level covering what each option or argument in a BCD /ENUM dump might mean, and the principles governing how these all work together. Imagine trying to rebuild or debug BCD (including EFI/BIOS variants and recovery/hibernate/memtest sections, and perhaps multiple boot Windows/WinPE/WinRE) from scratch using just BCDedit + DiskPart, and trying to understand rather than just copy/pasting commands. That's roughly the knowledge I'm after. Example questions might be: How is a BCD /ENUM dump to be read, item by item? How do its sections work together? (A lot of guides only show a specific example rather than explaining all the all common args that can exist and what they mean, they don't actually explain how sections work together, or they assume MBR/BIOS/Vista/7 and omit info needed for EFI/GPT/Dynamic disks/8) Partitions are specified by volume letter or as a \Device\HarddiskVolumeNNN. Why does it sometimes show these items as a letter and sometimes as a GUID? What are the practical differences if any? What exactly is syntax like "ramdisk=[C:]\Images\winpe.wim,{ramdiskoptions}" saying, and how will the drive letter "C" be interpreted at runtime in a line like this? Is the drive in such a line always "C:" (most examples assume so) and if not, when wouldn't it be? Many websites state that an sdi device and path may be needed in some sections of BCD, but what is sdi and what are these args doing when they appear? How does the GUID to HDD volume/partition mapping work under EFI/GPT? So that if disks or partitions/volumes change it's clear how one can confirm from basic principles whether data shown in BCD /ENUM ALL is still correct or not. Does anyone know of a suitable reference source for this kind of raw BCD data and structures? Thanks!

    Read the article

  • Dual booting Linux/Win7, Grub refuses to load Win7

    - by JohnB
    Decided to give Linux Mint a try (Ubuntu's interface annoys me), so I installed it with the intention of dual booting with Windows 7. Installation went fine, but now I can only boot into Linux Mint. Grub lists two Windows 7 menu options, but selecting either of them causes an "unknown file system" error and dumps me into a Grub recovery prompt. There, I have to manually reset the root and prefix options, as they reset hd0,msdos6 when they should be hd0,msdos5. I ran Boot Repair twice, once to fix grub errors, once to rebuild the MBR, but it didn't fix anything. Here is the log: http://paste.ubuntu.com/1029675/ fdisk output: Device Boot Start End Blocks Id System /dev/sda1 * 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 206848 1486249145 743021149 7 HPFS/NTFS/exFAT /dev/sda3 1486249982 1953523711 233636865 5 Extended /dev/sda5 1486249984 1945141247 229445632 83 Linux /dev/sda6 1945143296 1953523711 4190208 82 Linux swap / Solaris grub.cfg: ### BEGIN /etc/grub.d/30_os-prober ### menuentry "Windows 7 (loader) (on /dev/sda1)" --class windows --class os { insmod part_msdos insmod ntfs set root='(hd0,msdos1)' search --no-floppy --fs-uuid --set=root 86184D18184D091F chainloader +1 } menuentry "Windows 7 (loader) (on /dev/sda2)" --class windows --class os { insmod part_msdos insmod ntfs set root='(hd0,msdos2)' search --no-floppy --fs-uuid --set=root 56D84F84D84F60FB chainloader +1 } ### END /etc/grub.d/30_os-prober ### I have found a few similar troubleshooting guides so far, but so far no amount of updating/configuring Grub has been successful. Last resort is, I suppose, use the W7 recovery disc and start over. Thanks in advance! Linux Mint 13 Maya, 64-bit Windows 7 Home Edition, 64-bit

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Fixing corrupt files or corrupt file table on a USB drive?

    - by Kelsey
    I was doing a virus scan on an external USB drive while copying data over to it. While AVG was scanning my system got locked up I think due to the USB drive running out of space and it required a reboot. Since that time all data on the external drive is no longer accessible. I can see all the files in the root and directories but I cannot browse into any of them as Windows 7 gives an error stating they are corrupt. I think the file table or whatever it uses to store the index of what exists on the drive has been corrupted since it still shows the the drive as being almost full but everything I do a properties check on says it is 0 bytes. Does anyone know how to 'unlock' or recover this data? Is there a way to rebuild the file table somehow? Luckily I can recover this data from other sources as a last resort but I would like to fix this if possible. Any help would be appreciated. Thanks.

    Read the article

  • SQL Full-Text indexing not populating

    - by Sam
    Hi, We installed a clustered SQL 2005 installation on windows 2008 and reattached our san drives from another machine and restored to do a migration to new hardware. There have been a few minor issues, but this one has me stuck. Trying to populate Full-Text indexes is not working. I create a basic table with some simple text in a new database and get the same results as old indexes. 2010-09-27 10:30:46.85 spid19s Informational: Full-text Full population initialized for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'). Population sub-tasks: 1. 2010-09-27 10:31:15.36 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001DF. Attempt will be made to reindex it. 2010-09-27 10:31:15.37 spid19s The component 'MSFTE.DLL' reported error while indexing. Component path 'D:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Binn\MSFTE.DLL'. 2010-09-27 10:31:15.37 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001E0. Attempt will be made to reindex it. The rebuild/repopulate procedure finishes, but I get zero rows in the index. The .dll in the message is present and the service accounts have access to this. My FTData also has data in it, so it seems there wouldn't be permission issue on this folder. Application throws this error: “PHP Warning: mssql_query() [function.mssql-query]: message: Full-text catalog 'ikm_PageIndex_FText' is in an unusable state. Drop and re-create this full-text catalog. (severity 16) in E:\Inetpub\knowledgebase_insidemesa\lib\database\mssql.php on line 154” A microsoft discussion is the only post I found which had claimed to fix this - said it was registry related, but then didn't post the fix.

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • Multiple PHP SAPI configuration

    - by DTest
    I'm trying to build PHP for use as an apache shared module --with-apxs2 but also with the 'php-cgi' binary (fastcgi) on Mac OSX 10.6. I'm using this ./configure : /configure --prefix=/usr/local/PHP \ --with-apxs2=/usr/local/apache/bin/apxs \ --disable-ipv6 \ --enable-cgi \ --with-curl \ --with-mysqli=/usr/local/mysql/bin/mysql_config \ --with-openssl=/usr \ --enable-ftp \ --enable-shared \ --enable-soap \ --enable-sockets \ --enable-zip \ --with-zlib-dir It builds the apache php5.so module just fine, but in /usr/local/PHP/bin, there is no php-cgi file. If I build it without the --with-apxs2 option (and indeed, I don't even need the --enable-cgi option) the php-cgi file gets built with no problems. Background on my setup: PHP 5.3.4, Apache 2.2.14, Mac OSX 10.6, Tomcat with JavaBridge (which is why I need the php-cgi file) Without the apxs2 option, /usr/local/php/bin/php -v produces: PHP 5.3.4 (cli) (built: Dec 21 2010 21:35:14) Copyright (c) 1997-2010 The PHP Group Zend Engine v2.3.0, Copyright (c) 1998-2010 Zend Technologies and /usr/local/php/bin/php-cgi -v produces: PHP 5.3.4 (cgi-fcgi) (built: Dec 21 2010 21:35:12) Copyright (c) 1997-2010 The PHP Group Zend Engine v2.3.0, Copyright (c) 1998-2010 Zend Technologies My question is, what am I not understanding with php SAPIs that won't allow the building of the two modules at the same time? Also, can I build it --with-apxs2 the first time, then make clean and rebuild in the same PHP directory /usr/local/php for the php files without issue?

    Read the article

  • Resize a RAID 1 volume on OSX Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OSX 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable...), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • Google Desktop Search problems - unable to disable indexing and no index status page

    - by Howiecamp
    I've been running Google Desktop (I've used both the regular and Enterprise versions) without issues on my Windows 7 64-bit PC for a long time with no issues. I just paved my PC and reinstalled Google Desktop (regular edition). Initially, I want to use it only for the CTRL-CTRL launcher capability - I don't want it to do any indexing. So I unchecked all the items in the configuration dialog as well as excluded c:. Despite this, it is indexing all the content on my hard drive as well as Outlook email, etc. In my previous installations I had the same options set and they worked properly. The other problem I have is that when you right-click on the Google Desktop system tray icon, there used to be an option for "Index Status" which showed you the percentage complete the index creation process was, as well as an option to clear and rebuild the index. Those are no longer there. I uninstalled the regular edition and installed the Enterprise Edition, but same problems. Any ideas?

    Read the article

  • cfengine3 file_copy only on source side change

    - by megamic
    I am using the 'digest' copy method for all file copy promises, because of the way we package and deploy software, I cant rely on mtime for the criteria for updating files. For various reasons, I am not employing the client-server approach with a central configuration server: rather we package and deploy our entire configuration module to each server, so from cf-engine's perspective, the source and target are local on the server it is running. The problem I am having with this approach is that the source will always update the target when they differ - which is what I want most of the time, usually because the source has been updated. However, like many other cfengine users, we are running an operational environment, where occasionally emergency fixes have to be applied immediately - meaning we don't have time to rebuild and redeploy a configuration module, and the fix will often be applied by deploying a tarball with specific changes. Of course this is problematic if cf-engine comes along 5 mintues later and reverts the changes. What we would like is to be able to make small, incremental changes to our servers, without them being reverted, until the next deployment cycle at which time the new source files would be copied. We do not consider random file corruption or mistaken changes to involve enough risk to warrant having cfengine constantly revert deployments to their source copy - the ability to deploy emergency fixes and have them stay that way until the next deployment would be of much greater value and utility. So, after all that, my question is this: is cf-engine capable of detecting whether it was the source or target that changed when the files differ, and if so, is their a way to use the 'digest' copy method but only if the source side changed? I am very open to other ideas and approaches as-well, as I am still quite new to this whole configuration management thing.

    Read the article