Search Results

Search found 19676 results on 788 pages for 'hardware interface'.

Page 331/788 | < Previous Page | 327 328 329 330 331 332 333 334 335 336 337 338  | Next Page >

  • The perfect server room?

    - by splattne
    What do I have to consider when I'm planning a new server room for a small company (30 PCs, 5 servers, a couple of switches, routers, UPS...)? What are the most important aspects in order to protect the hardware? What things do not belong in a server closet? Edit: You may also be interested in this question: Server Room Survival Kit. Thank you!

    Read the article

  • Persistent Issues on small business network using Cisco 871W and Catalyst Express 500

    - by Ben Campbell
    Being the most qualified (read: still not qualified) to solve our persistant network issues, I've turned to serverfault for guidance. I've done some searching, reading related documentation on cisco.com and tried a bit of troubleshooting. Here is the config: 100mb synchronous connection from a business internet provider (tested multiple times at 100meg at the source) Cisco 871W wireless point & router is where the WAN connection starts (this serves all our wireless). The only wired connection in the 871W is the Catalyst switch listed below. Cisco Catalyst Express 500 (24TT) is where all the wired connections terminate. About 20 Windows workstations and servers (AD/Webservers only). Some services in EC2 including mail and other web servers/apps. I've been TOLD cabling internally should be gigabit-ready. Here are the problems: generally slow download rates from the internet to the desktop/laptop frequent "page cannot be displayed" errors in browsers-sometimes 3 or 4 reloads are necessary... often times CSS wont load or other content requiring the browser to connect to a different server. slow speed within the LAN from workstation to workstation copying files. I would expect extremely fast data transfer workstation to workstation / server to workstation in this simple network. Several things I need to admit: I'm not primarily a network guy. Funding is relatively low, I need to be the guy that finds the solution. I understand most of the terminology and most of the technology. Implementation is where I fail due to lack of experience. Getting to the point: I'm wondering whether experienced network admins think that our small network should be sufficiently served with our current hardware if configured properly... or if we should purchase new equipment and start fresh? If starting fresh is the plan, whatever that new equipment may be is a likely different question entirely. If I haven't provided enough information, I will happily do some troubleshooting and update with the results. I have experience using wireshark and some other tools. Please let me know what you think would be most helpful and thanks in advance. EDIT: I forgot to add that the Cisco applicance will not finish loading the SDM Express console. It hangs every time at the "populating modules... DHCP". It eventually crashes and closes. I've rebooted the hardware and this still happens.

    Read the article

  • Is Splitting IDE hdds between Primary and Secondary faster?

    - by earlz
    Hello, I'm doing RAID 0 on two IDE harddrives (yes, this is old hardware). Will the harddrives be faster if I attach them separately so that one is on the Primary IDE controller and the other is on the Secondary IDE controller? Or would it just be as good as having them both on the Primary IDE as master and slave?

    Read the article

  • How to detect VPN disconnection with vpnc?

    - by Abhinav
    What is the easiest way to detect that a vpnc connection on Linux/Ubuntu has disconnected? Manually, I think the way to detect is to check whether the interface (tun0) appears in /sbin/ifconfig output. Is there a better way to find out immediately, so that a script can be run to restart the connection?

    Read the article

  • Squid 2.7.STABLE3-4.1 as a transparent proxy on Ubuntu Server 9.04

    - by LOGIC9
    Can't get this to work at all! I'm trying to get this linux box to act as a transparent proxy and, with the help of DHCP, force everyone on the network to gate into the proxy. I have two ethernet connections, both to the same switch. And I'm trying to get 192.168.1.234 to become the default gateway. The actual WAN connection is to a gateway 192.168.1.1. eth0 is 192.168.1.234 eth1 is 192.168.1.2 Effectively I'm trying to make eth0 a LAN only interface and eth1 a WAN interface. I've oi should set the gateway for eth1 to point to 192.168.1.234 my squid.conf file has the following directives added at the bottom: nly set eth0 to have a gateway address in /etc/network/interfaces I'm not sure whether http_port 3128 transparent acl lan src 192.168.1.0/24 acl lh src 127.0.0.1/255.255.255.0 http_access allow lan http_access allow lh i've added the following routing commands: iptables -t nat -A PREROUTING -i eth0 -p tcp -m tcp --dport 80 -j DNAT --to-destination 192.168.1.2:3128 iptables -t nat -A PREROUTING -i eth1 -p tcp -m tcp --dport 80 -j REDIRECT --to-ports 3128 I set a computer with TCP settings 192.168.1.234 as the gateway and opened up google.com, but it comes up with a request error. Any ideas why this isn't working? :( Been searching continuously for a solution to no avail. ----------------------------- EDIT ------------------------------- Managed to get it to route properly to the squid, here's the error I get in the browser: ERROR The requested URL could not be retrieved While trying to process the request: GET / HTTP/1.1 Host: www.google.com User-Agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-GB; rv:1.9.1.2) Gecko/20090729 Firefox/3.5.2 Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 Accept-Language: en-gb,en;q=0.5 Accept-Encoding: gzip,deflate Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7 Keep-Alive: 300 Connection: keep-alive Cache-Control: max-age=0 The following error was encountered: * Invalid Request Some aspect of the HTTP Request is invalid. Possible problems: * Missing or unknown request method * Missing URL * Missing HTTP Identifier (HTTP/1.0) * Request is too large * Content-Length missing for POST or PUT requests * Illegal character in hostname; underscores are not allowed Your cache administrator is webmaster. Generated Mon, 26 Oct 2009 03:41:15 GMT by mjolnir.lloydharrington.local (squid/2.7.STABLE3)

    Read the article

  • Nvidia driver for Dell xps M1330 in XP

    - by Recursion
    I need to run xp, and cannot find a driver that works for this laptop in windows xp. I have tried quite a few of them, from my google searches, but none work, they all come up and say no proper driver can be found for your hardware. I have tried to replace the inf files on driver installs but I still get nothing, same error. Any ideas will be appreciated, thank you.

    Read the article

  • Internet Sharing via router

    - by mak4pi
    Question: How to setup Internet Sharing among two computers (one Mac 10.5.6, one Ubuntu 9.10) via a router? Situation: The Mac is using AirPort (wireless interface) to connect to router as 192.168.1.101. The Ubuntu is using an ethernet cable to connect to router as 192.168.1.104. Visual: Mac )))))) Router ======= Ubuntu Any ideas are greatly appreciated. Thanks.

    Read the article

  • Spanning-tree setup with incompatible switches

    - by wfaulk
    I have a set of eight HP ProCurve 2910al-48G Ethernet switches at my datacenter that are set up in a star topology with no physical loops. I want to partially mesh the switches for redundancy and manage the loops with a spanning-tree protocol. However, our connection to the datacenter is provided by two uplinks, each to a Cisco 3750. The datacenter's switches are handling the redundant connection using PVST spanning-tree, which is a Cisco-proprietary spanning-tree implementation that my HP switches do not support. It appears that my switches are not participating in the datacenter's spanning-tree domain, but are blindly passing the BPDUs between the two switchports on my side, which enables the datacenter's switches to recognize the loop and put one of the uplinks into the Blocking state. This is somewhat supposition, but I can confirm that, while my switches say that both of the uplink ports are forwarding, only one is passing any real quantity of data. (I am assuming that I cannot get the datacenter to move away from PVST. I don't know that I'd want them to make that significant of a change anyway.) The datacenter has also sent me this output from their switches (which I have expurgated of any identifiable info): 3750G-1#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 5 (GigabitEthernet1/0/5) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 0018.73d3.yyyy Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/5 Root FWD 4 128.5 P2p Gi1/0/6 Altn BLK 4 128.6 P2p Gi1/0/8 Altn BLK 4 128.8 P2p and: 3750G-2#sh spanning-tree vlan nnn VLAN0nnn Spanning tree enabled protocol ieee Root ID Priority 10 Address 00d0.0114.xxxx Cost 4 Port 6 (GigabitEthernet1/0/6) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32mmm (priority 32768 sys-id-ext nnn) Address 000f.f71e.zzzz Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Gi1/0/1 Desg FWD 4 128.1 P2p Gi1/0/5 Altn BLK 4 128.5 P2p Gi1/0/6 Root FWD 4 128.6 P2p Gi1/0/8 Desg FWD 4 128.8 P2p The uplinks to my switches are on Gi1/0/8 on both of their switches. The uplink ports are configured with a single tagged VLAN. I am also using a number of other tagged VLANs in my switch infrastructure. And, to be clear, I am passing the tagged VLAN I'm receiving from the datacenter to other ports on other switches in my infrastructure. My question is: how do I configure my switches so that I can use a spanning tree protocol inside my switch infrastructure without breaking the datacenter's spanning tree that I cannot participate in?

    Read the article

  • after installing monit when i do monit status myproc i get "error connecting to the monit daemon"

    - by Jason
    after installing monit when i do monit status myproc i get "error connecting to the monit daemon" I read somewhere that The status command won't work in the case that monit is running indaemon mode without its http support - the command 'monit status' in such case tries to get the status from the daemon via http/tcp. To start the http interface you need to add the 'set httpd ...' statement to theconfiguration. is that still correct? that post was from 2005

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • Create an AWS HVM Linux AMI from an Existing Paravirtual Linux AMI

    - by javacavaj
    Is it possible to create a hardware virtual machine (HVM) AMI from an existing paravirtual (PV) AMI. My initially thought was to start a new PV instance and use the ec2-create-image command to create a new image while specifying HVM as the virutalization type. However, ec2-create-image does not have a command line parameter to specify the virtualization type. Is there another way to go about doing this?

    Read the article

  • Biometric access control for time-reporting system

    - by dam
    I made a simple REST application to control the presence of workers. Now I'm looking for an inexpensive (100-250$) hardware, possibly linux based, with a fingerprint reader from which I can perform the user authentication and interact with the application (both the activities) via REST. I saw hundreds of different devices on internet which are supposed to do these activities but there are no good datasheets for them and it's very difficult to understand what's possible to do with those devices. Do you have any suggestions for me? Thanks

    Read the article

  • Installing Windows server 2008 on not VT system

    - by Shahid
    I have a Dell Inspiron 1440 laptop and it has no virtualization support, i want to install Windows Server 2008 on it using Virtual Box, i know that we can install Mac OS on not Virtualization supported system using some patch. I also haired that Virtual box don't needs hardware virtualization, it will do that using software virtualization. how can i achieve that, any guidance would be very nice. Thanks

    Read the article

  • Temperature monitoring on Dell Precision M4500 under Linux: sensors-detect doesn't, what next?

    - by Tikitu
    I have a Dell Precision M4500, Intel Core i5 CPU, running Linux (Ubuntu Lucid), and would like to keep an eye on CPU temperature. I've tried lm-sensors: sensors-detect didn't find any sensors; following its hint ("This is relatively common on laptops, where thermal management is handled by ACPI rather than the OS.") I tried acpi -V but got nothing thermal. The Gnome panel applet "Hardware Sensors Monitor" reports on GPU temperature but nothing else. What should I be trying next?

    Read the article

  • Archlinux/atheros WLAN configuration troubles

    - by GrinReaper
    I'm trying to config archlinux to use my wireless network adapter. It's quite troublesome. From what I've gathered, it's an atheros network adapter, using the ath5k driver/module... I can't get it to work; any ideas? Here's some of the output from my tinkering: # lspci | grep -i net 00:0a.0 Ethernet controller: nVidia corporation MCP67 Ethernet (reva2) 03:00.0 Ethernet controller: atheros communications inc. AR5001 Wireless Network Adapter (rev01) # lsusb ... Bus 004 Device 003: ID 03f0:17d Hewlett Packard Wireless (Bluetooth + WLAN Interface [Integrated Module] # ping -c 3 www.google.com ping: unknown host www.google.com #ping -c 3 8.8.8.8 ping: network is unreachable # lspci -v 03:00.0 Ethernet controller: atheros communications inc. AR5001 Wireless Network Adapter (rev01) ... Kernel driver in use: ath5k Kernel modules: ath5k # dmesg |grep ath5k registered as phy0 registered led device ath5k: atheros chip found PCI INT A disabled registered led device registered as phy1 # ip addr | sed '/^[0-9]/!d;s/: <.*$//' 1: lo 2: eth1 3: eth0 # ip link set <interface> up/down RNETLINK answers: Operation not possible due to RF-kill Also, is there a way to dump text from command-line to a text file so i can just copy pasta? Sorry, first time using a linux distro... EDIT: So I just tried this: I actually just did this twice. (I can't tell which setting is on/off for my wireless adapter. The lights are blue all the time now.) #rfkill list 0: hp-wifi: wireless lan softblocked: no hardblocked :yes 1: hp-bluetooth: bluetooth softblocked: no hardblocked :yes 3: phy1: wireless lan softblocked: no hardblocked :yes #rfkill list 0: hp-wifi: wireless lan softblocked: no hardblocked :no 1: hp-bluetooth: bluetooth softblocked: no hardblocked no 3: phy1: wireless lan softblocked: no hardblocked :yes 7: hci0: bluetooh 0: hp-wifi: wireless lan softblocked: no hardblocked :no I've dug around some other articles and it seems like ath5k is supposed to be preferable to madwifi, so should i be using madwifi? I'm 99% sure I disabled the hardblock (by turning it ON) but, as shown above, phy1 wireless lan is STILL hardblocked. What gives? Maybe I've made some more fundamental error in a basic config file? EDIT: I've fixed the hardblock. I've tried pinging www.google.com, but to no avail. I get: ping: unknown host www.google.com In the arch wiki: Edit /etc/hosts and add the same HOSTNAME you entered in /etc/rc.conf: 127.0.0.1 archlinux.domain.org localhost.localdomain localhost archlinux To my understanding, hostname is just a user-specified and based on preference(?) My /etc/rc.conf: HOSTNAME="gestalt" My /etc/hosts: 127.0.0.1 localhost.localdomain localhost gestalt but should it be the following? 120.0.0.1 localhost.domain.org localhost.localdomain localhost gestalt

    Read the article

  • remove addons from internet explorer 8 [closed]

    - by senthil
    Possible Duplicate: Why is it not possible to delete IE addons from the IE interface? In my "Manage Addons" dialog, there are lots of addons that I have no idea about. I never installed Java on my machine but a java addon is there. Then some other things. I am only able to disable them. How can I remove them and all the related files?

    Read the article

  • What is the best BitTorrent client for Mac OS X?

    - by deddebme
    I am using uTorrent in Mac OS X but I wasn't happy about it at all. It is much worse than its Windows version and it hasn't been updated for quite a while. I tried Azureus but its interface isn't good, probably because it is Java based. Any recommendation on which BitTorrent client to use in Mac OS X?

    Read the article

  • Shouldn't WP8 Emulator Work With an Intel Q9650?

    - by Al Bundy
    My comp is as follows: -Windows 8 Pro -Visual Studio 12 Pro -Asus P5Q Pro Turbo -Intel Q9650 (Core 2 Quad 3.0 Ghz) As far as I can tell, this setup should support Windows Phone 8 Emulator, but When I installed Windows Phone 8 SDK, it said that my computer doesn't support hardware virtualization. It says here that it does: http://ark.intel.com/products/35428/Intel-Core2-Quad-Processor-Q9650-(12M-Cache-3_00-GHz-1333-MHz-FSB)

    Read the article

  • No audio from USB device on iMac

    - by brandon
    My computer froze the other day and started a buzzing noise. After I restarted in the middle of it, the buzzing persisted. A few restarts later, the buzzing stopped, but I can't get audio to come from my audio interface setup anymore. I'm using an M-Audiophile USB to connect to studio monitors, and there's absolutely no audio. I've tried restarting many times and unplugging - still nothing. Any help would be appreciated.

    Read the article

  • Any rerefence of CPU world statistics?

    - by Áxel Costas Pena
    I am looking for any referencee about computer power statistics across the world. My main interest is about real computing capabilities, so I'd prefer information about real processor power, and even best if it includes also other critical hardware statistics, like RAM memory, but if it isn't possible, maybe statistics about brand/model distribution will be also useful. I've Googled for some minutes and I've found nothing related.

    Read the article

  • Does Windows 7 RC handle non Windows Media Center remotes yet?

    - by zillion
    I'm mostly a Linux geek, but while I will be trying to make my first Arch Linux installation in a virtual machine to learn and make my installation script for the true install, I need a simple OS and Windows 7 was better than Windows XP Media Center cause Media Center is outdated on XP. I tested it has a beta but my Hauppauge wintv-pvr usb2 remote wasn't working but the tv-tuner worked well and I haven't tested Windows XP Mode and my printer Epson Stylus Photo R300. Do someone know this hardware and if the XP Mode is easily supported?

    Read the article

  • Machine check events logged

    - by GoldenNewby
    In /var/log/messages, this error occurred: Sep 19 13:18:15 wdc kernel: [2772302.630416] Machine check events logged Shortly there after, the entire server became unresponsive. This is in the log of the Dom0 for a Xen Server (running the latest version on Debian Squeeze). Can anyone shed some light on what this error means? Should I be ordering new hardware? Edit: Also, it seems to imply it logged something, where can I find that?

    Read the article

  • Unable to install sbs 2008 in DELL POWEREDGE T100 [closed]

    - by Swaminathan Shanmugam
    Still unable to install WIN SBS 2008 in DELL POWEREDGE T100 server and the long post is going on at http://social.technet.microsoft.com/Forums/en-US/winservergen/thread/aa1bc4b0-943e-4ada-8de1-e03161c8fc2c My problem is unable to install sbs 2008 in 500 GB 4k sectors hdd but installation is successful in 512 bytes sector hdd. Anybody please help to solve this issue? Installation of SBS 2008 proceeds ; atlast it is not getting completed with the error message "Windows Setup could not configure Windows on this computer’s hardware"

    Read the article

< Previous Page | 327 328 329 330 331 332 333 334 335 336 337 338  | Next Page >