  • hp proliant dl360 disk diagnostic issue

    - by user1039384
    We recently got two used drives (15000) and installed on our HP proliant dl360 G5 server. Created RAID1 and used HP SmartStart CD to perform diagnostics. Interestingly, the Diagnostic tab immidiately fails on Logical drive testing saying the Disk1 should be replaced, while the Test tab successfully runs all the complete tests on both disks and does not find any issue. At the meantime, when booting to esxi 5, vSphere periodically shows the Disk1 as Unknown and Logical drive in recovery process. This happens every 5-10 minutes. Here is the log from HP SmartScan diagnostic: 1 - Device, Test: Logical Drive 1, Storage Controller in Slot 0 1 - Description: The controller has reported a critical error in the drive error log. 1 - Recommended Repair: This drive should be replaced. 1 - Failed Count: 44 1 - Error code: F157 There is also another error log record (see below): 2 - Device, Test: test_components/libstorage.so ID 2 - Description: An unexpected exception occurred while performing an operation. Exception message: CISS_StatusHandler::evaluate: commandStatus = 4 (INVALID); hexdump of CISS_ErrorInfo: 00000000: __ __ 04 __ 20 __ __ __ __ __ __ __ __ __ __ __ .... ... ........ 00000010: __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ ........ ........ 00000020: __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ ........ ........ Device: Hard Drive 2, Storage Controller in Slot 0 Property name: Bad Target Count 2 - Recommended Repair: Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics. 2 - Failed Count: 48 2 - Error Code: F62 Note that rebooting didn't help and I was running the latest diagnostic software version. Anyone has a clue? Is this a real disk issue? BTW, the controller is Smart Array E200i Thanks in advance

    Read the article

  • HP proliant dl360 g5 fails to reboot

    - by user1039384
    Some history of this also available here. As of my latest update on the forum linked above, now cold reboot as well as hard reset and following boot for my proliant dl360 g5 works as expected and successfully boot the system. However, soft-reboot results in internal health indicator turning RED on the front and long beeps every around 6seconds until I either cold reboot or press and hold the power button. A summary of system state when this happens: Internal Health led indicator: RED External Health led indicator: Green No led next to any component is red or amber No POST message neither on the video output nor on IML logs (verified both at the time issue occures and after cold reboot that boots the system successfully). Any thoughts please share. I hope we can knock this issue down together with your help!

    Read the article

1